Popis
BHT INNOVA E3 Professional Bronchoscope Washer-Disinfector
INNOVA – Professional endoscope washer-disinfector for practices and small clinics
The INNOVA™ E3s is the world’s best-selling BHT endoscope washer-disinfector. This endoscope washer is compact yet offers high capacity for endoscopes or bronchoscopes. Depending on the reprocessing protocol, a total of 10 to 20 endoscope cycles per day is possible. This makes it the ideal solution for private practitioners and small clinics that prioritize reliable hygiene, efficiency, and dependability.
Reliability and superior cleanliness with every cycle:
Meets DIN EN ISO 15883-1/-4 as well as RKI guidelines, with multiple additional features such as thermal self-disinfection at 90°C (according to DIN EN ISO 15883-4, section 4.8.1).
- Flexible: Can be combined with another INNOVA® E2 or E3 for up to 30 to 40 cycles per day.
- Compatible with both glutaraldehyde and peracetic acid from a wide range of suppliers.
- Suitable for commercial endoscopes from Fuji, Olympus, Pentax, Storz, Wolf.
- Single-channel connection or patented pressure chamber available.
- Option for thermal processing, e.g. multiple biopsy forceps, polypectomy snares, etc.
- Thermal disinfection of final rinse water as recommended by the RKI (with DH version).
- Secure documentation and traceability via batch control. Operator and endoscope tracking via barcode scanner.
Fpsdpfoin Edwjx Af Eod
- Data output via printer, data logger, or interface. Easy integration into existing IT systems.
Number of endoscopes: For 2 endoscopes or 4 ENT scopes
Hygiene concept: Hygienic workflow, single-door design
Channel connection system: Single-channel connection or patented pressure chamber system possible
Single channel control (CMS): No
Chemistry: Glutaraldehyde / Peracetic acid: Both possible: Version DH (with boiler, for glutaraldehyde) or DC (filtration solution, for glutaraldehyde or peracetic acid)
Documentation and integration: Yes, interface for printer/data logger standard. Printer included. Optional scanner/IT interface.
Thermal processing of instruments at 90°C: Possible with additional equipment
Electrical installation: 3ph 400V / 50Hz AC+N+PE. Connected load: 11 kW. Fusing: 3 x 20 A
Year of construction: 19.01.2013
Condition: Used
Financing through our partner bank is available.
komplett-konzept.leasingo.de
See our shop for more new and used items!
International shipping costs on request!
Inzerát bol automaticky preložený. Chyby v preklade sú možné.
INNOVA – Professional endoscope washer-disinfector for practices and small clinics
The INNOVA™ E3s is the world’s best-selling BHT endoscope washer-disinfector. This endoscope washer is compact yet offers high capacity for endoscopes or bronchoscopes. Depending on the reprocessing protocol, a total of 10 to 20 endoscope cycles per day is possible. This makes it the ideal solution for private practitioners and small clinics that prioritize reliable hygiene, efficiency, and dependability.
Reliability and superior cleanliness with every cycle:
Meets DIN EN ISO 15883-1/-4 as well as RKI guidelines, with multiple additional features such as thermal self-disinfection at 90°C (according to DIN EN ISO 15883-4, section 4.8.1).
- Flexible: Can be combined with another INNOVA® E2 or E3 for up to 30 to 40 cycles per day.
- Compatible with both glutaraldehyde and peracetic acid from a wide range of suppliers.
- Suitable for commercial endoscopes from Fuji, Olympus, Pentax, Storz, Wolf.
- Single-channel connection or patented pressure chamber available.
- Option for thermal processing, e.g. multiple biopsy forceps, polypectomy snares, etc.
- Thermal disinfection of final rinse water as recommended by the RKI (with DH version).
- Secure documentation and traceability via batch control. Operator and endoscope tracking via barcode scanner.
Fpsdpfoin Edwjx Af Eod
- Data output via printer, data logger, or interface. Easy integration into existing IT systems.
Number of endoscopes: For 2 endoscopes or 4 ENT scopes
Hygiene concept: Hygienic workflow, single-door design
Channel connection system: Single-channel connection or patented pressure chamber system possible
Single channel control (CMS): No
Chemistry: Glutaraldehyde / Peracetic acid: Both possible: Version DH (with boiler, for glutaraldehyde) or DC (filtration solution, for glutaraldehyde or peracetic acid)
Documentation and integration: Yes, interface for printer/data logger standard. Printer included. Optional scanner/IT interface.
Thermal processing of instruments at 90°C: Possible with additional equipment
Electrical installation: 3ph 400V / 50Hz AC+N+PE. Connected load: 11 kW. Fusing: 3 x 20 A
Year of construction: 19.01.2013
Condition: Used
Financing through our partner bank is available.
komplett-konzept.leasingo.de
See our shop for more new and used items!
International shipping costs on request!
Inzerát bol automaticky preložený. Chyby v preklade sú možné.
Poskytovateľ
Poznámka: Zaregistrujte sa zadarmo alebo sa prihláste, aby ste získali všetky informácie.
Registrovaný od: 2008
590 Inzeráty online
Odoslať dopyt
Telefón & Fax
+49 2862 ... inzercie
Tieto inzeráty by vás mohli tiež zaujímať.
Malý inzerát
Zuchwil
919 km
Zariadenie na čistenie a dezinfekciu
MMM = Münchener Medizin MechanikUniclean® PL II 15
MMM = Münchener Medizin MechanikUniclean® PL II 15
Malý inzerát
Wald
783 km
Sterilizátor endoskopu Steril
SterisEPS
SterisEPS
Malý inzerát
Duxford
1 433 km
Umývačka skleneného riadu SMEG GW1160
SMEGGW1160
SMEGGW1160
Váš inzerát bol úspešne odstránený
Došlo k chybe