Klimatická skúšobná komora 350 litrov Ex/lCTS
C-40/350 Ex/l -40°C /+180°C
Klimatická skúšobná komora 350 litrov Ex/l
CTS
C-40/350 Ex/l -40°C /+180°C
Stav
Použitý
Umiestnenie
Borken 

Zobraziť obrázky
Zobraziť mapu
Údaje o stroji
Cena a lokalita
- Umiestnenie:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Volať
Podrobnosti ponuky
- ID záznamu:
- A19446591
- Referenčné č.:
- 24669
- Naposledy aktualizované:
- dňa 27.06.2025
Popis
CTS
Type: C-40/350 Ex/l
Climatic Test Chamber, Water-cooled
ATEX Zone 1
The 'Ex/l' designation indicates that this climatic test chamber is suitable for use in hazardous areas classified as Zone 1.
This means it is intended for environments where explosive atmospheres may occur.
Such equipment is specially designed and tested to ensure safety in these conditions.
Temperature Testing:
Temperature range: -40°C to +180°C
Temperature deviation: ≤ ±0.3 K (over time)
Temperature change rate according to IEC 60068-3-5:
Heating: 3.5 K/min
Cooling: 4 K/min
Heat compensation:
approx. 3500 W at +20°C
approx. 2000 W at -20°C
Climate Testing:
Temperature range: +10°C to +90°C
Humidity range: 10% to 95% relative humidity
Dew point range: +5°C to +78°C
Temperature deviation: ≤ 1.0 K (over time)
Humidity deviation: ≤ +3.0% rH (over time)
All technical data refer to an ambient temperature of +25°C, rated voltage 400V, without test specimen, without heat compensation, and without additional equipment. Options may affect performance data.
Technical Specification:
Refrigeration unit: water-cooled, low noise, fully hermetic, infinitely variable capacity adjustment via electronic monitoring and control system, environmentally friendly refrigerant R404A
Test chamber floor load capacity: 150 kg/m²
Wire shelf: stainless steel, usable area 620 x 600 mm, max. load per shelf 35 kg, total load with max. number of shelves 100 kg
Iaodpfx Aowvr H Uogtol
Control:
32-bit controller
LCD control panel
Digital display of setpoint and actual values
Numeric input for setpoints
Plain text fault messages
RS 232 interface
Ethernet interface
Free control channels for customer-specific test specimen control
Dimensions:
Test volume: 350 liters
Internal dimensions: height 750 mm × width 650 mm × depth 720 mm
External dimensions: height 1800 mm × width 850 mm × depth 1640 mm
Operating Data:
Electrical connection: 400 V +6/-10%, 3/N, 50 Hz
Rated power: 7.15 kW
Rated current: 14.3 A
Protection class: IP54
Sound pressure level:
Inzercia bola automaticky preložená a vyskytli sa nejaké chyby prekladu.
Type: C-40/350 Ex/l
Climatic Test Chamber, Water-cooled
ATEX Zone 1
The 'Ex/l' designation indicates that this climatic test chamber is suitable for use in hazardous areas classified as Zone 1.
This means it is intended for environments where explosive atmospheres may occur.
Such equipment is specially designed and tested to ensure safety in these conditions.
Temperature Testing:
Temperature range: -40°C to +180°C
Temperature deviation: ≤ ±0.3 K (over time)
Temperature change rate according to IEC 60068-3-5:
Heating: 3.5 K/min
Cooling: 4 K/min
Heat compensation:
approx. 3500 W at +20°C
approx. 2000 W at -20°C
Climate Testing:
Temperature range: +10°C to +90°C
Humidity range: 10% to 95% relative humidity
Dew point range: +5°C to +78°C
Temperature deviation: ≤ 1.0 K (over time)
Humidity deviation: ≤ +3.0% rH (over time)
All technical data refer to an ambient temperature of +25°C, rated voltage 400V, without test specimen, without heat compensation, and without additional equipment. Options may affect performance data.
Technical Specification:
Refrigeration unit: water-cooled, low noise, fully hermetic, infinitely variable capacity adjustment via electronic monitoring and control system, environmentally friendly refrigerant R404A
Test chamber floor load capacity: 150 kg/m²
Wire shelf: stainless steel, usable area 620 x 600 mm, max. load per shelf 35 kg, total load with max. number of shelves 100 kg
Iaodpfx Aowvr H Uogtol
Control:
32-bit controller
LCD control panel
Digital display of setpoint and actual values
Numeric input for setpoints
Plain text fault messages
RS 232 interface
Ethernet interface
Free control channels for customer-specific test specimen control
Dimensions:
Test volume: 350 liters
Internal dimensions: height 750 mm × width 650 mm × depth 720 mm
External dimensions: height 1800 mm × width 850 mm × depth 1640 mm
Operating Data:
Electrical connection: 400 V +6/-10%, 3/N, 50 Hz
Rated power: 7.15 kW
Rated current: 14.3 A
Protection class: IP54
Sound pressure level:
Inzercia bola automaticky preložená a vyskytli sa nejaké chyby prekladu.
Poskytovateľ
Poznámka: Zaregistrujte sa zadarmo alebo sa prihláste, aby ste získali všetky informácie.
Odoslať žiadosť
Telefón & Fax
+49 2861 ... inzercie
Tieto inzeráty by vás mohli tiež zaujímať.
Malý inzerát
Butzbach
818 km
Obrábacie centrum
Starrag-HeckertHEC500D
Starrag-HeckertHEC500D
Malý inzerát
Nauen
656 km
Rozpúšťač Vollrath EWFX 60
Dissolver VollrathEWFX 60
Dissolver VollrathEWFX 60
Malý inzerát
Tatabánya
155 km
Povrchové brúsky Povrchové brúsenie
JungHF 50 (2338)
JungHF 50 (2338)
Malý inzerát
Ruhla
714 km
5-osová frézka
Deckel MahoDMU 70 eVlin
Deckel MahoDMU 70 eVlin
Malý inzerát
Wilbertoord
1 045 km
Obrábacie centrum - vertikálne
DMGDMU 40 Mono Block
DMGDMU 40 Mono Block
Malý inzerát
Sinsheim
792 km
Rozpúšťač
Schneider Maschinenbau GmbhSHDC15 KWFU Ex
Schneider Maschinenbau GmbhSHDC15 KWFU Ex
Malý inzerát
Nauen
656 km
Prietokový miešač M-tec D 10
Durchlaufmischer M-tecD 10
Durchlaufmischer M-tecD 10
Malý inzerát
Arnsberg
892 km
Mixaco Mixer CM 1000
MixacoCM 1000
MixacoCM 1000
Malý inzerát
Sinsheim
792 km
Použitý miešač Ploughshare
MAPWBHP 15000
MAPWBHP 15000
Malý inzerát
Borken
977 km
Klimatická skúšobná komora 335 litrov s vlhkosťou
VötschVCS 7034-5 -70°C bis +180°C
VötschVCS 7034-5 -70°C bis +180°C
Váš inzerát bol úspešne odstránený
Došlo k chybe