Teplotná skúšobná komora 1000 litrovCTS
T-55/1000 Li -50°C bis 100°C
Teplotná skúšobná komora 1000 litrov
CTS
T-55/1000 Li -50°C bis 100°C
Stav
Použitý
Umiestnenie
Borken 

Zobraziť obrázky
Zobraziť mapu
Údaje o stroji
Cena a lokalita
- Umiestnenie:
- Einsteinstraße 8a, 46325 Borken, DE
Volať
Podrobnosti ponuky
- ID záznamu:
- A17859456
- Referenčné č.:
- 24460
- Naposledy aktualizované:
- dňa 29.11.2024
Popis
CTS
Temperature Test Chamber T-55/1000 Li, Water-Cooled
Temperature Range: -50°C to +100°C
Rated Voltage: 400V 3/N 50Hz
Rated Power: 9.5 kW
Rated Current: 18 A
Compressor: TFH2511Z / TFH2511Z, Refrigerants R404A/R23
Model designation of the CTS cabinet series is structured as follows:
e.g., Type T -55/1000/Li
1) T stands for: Temperature
2) -55 indicates: minimum temperature -55°C
3) 1000 indicates: 1000-liter test chamber volume
4) Li indicates: special configuration for tests with lithium-ion accumulators
Control:
32-bit controller
LCD control panel
Digital display of set and actual values
Numerical setpoint input
Error messages in plain text
Ethernet interface
RS 232 interface
Free switching channels for customer-side test item control
Test Chamber Lighting:
Energy-efficient, high-intensity LED light bar mounted on the door
Rack:
Stainless steel, usable area 970 x 980 mm
Max. load per rack: 35 kg
Total load with maximum rack installation: 100 kg
Feedthroughs:
1x NW50
2x NW125
2x Rp 3 1/4° for Minimax
Technical Performance Data:
Temperature Testing:
Temperature range: -50°C to +100°C
Fgsdpfxsvba Ras Aguoh
Temperature deviation: ≤ ±0.3 K over time
Temperature change rate according to IEC 60068-3-5
Heating: 2.5 K/min
Cooling: 2.5 K/min
Thermal compensation:
Approx. 4000 W at +20°C
Approx. 2200 W at -40°C
The technical specifications refer to an ambient temperature of +25°C, rated voltage 400V, without test item, thermal compensation, or additional equipment. Options may affect performance data.
Dimensions:
Test volume: 1000 liters
Internal dimensions (approx.): Height 1000 mm, Width 860 mm, Depth 1100 mm
External dimensions (approx.): Height 1950 mm, Width 1270 mm, Depth 1900 mm
Operating Data:
Electrical connection: 400 V +6/-10%, 3/N, 50 Hz
Rated current: 18 A
Rated power: 9.5 kW
Degree of protection: IP 54
Sound pressure level: < 58 dB(A) (measured according to DIN EN ISO 3744 at 1m distance from the front)
Weight approx. 1000 kg
Heat emission to installation area: 10.4 kW
Cooling Unit:
Water-cooled, low-noise, fully hermetic
Stepless power control via electronic monitoring and control system
Environmentally friendly refrigerants R404A/R23
Important Safety Information for Buyers!
The following steps are performed on our offered chambers prior to delivery:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant if required
3. Leak test with certificate
4. Upon successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Technical data subject to change and errors reserved!)
Further questions can be answered by phone.
Inzercia bola automaticky preložená a vyskytli sa nejaké chyby prekladu.
Temperature Test Chamber T-55/1000 Li, Water-Cooled
Temperature Range: -50°C to +100°C
Rated Voltage: 400V 3/N 50Hz
Rated Power: 9.5 kW
Rated Current: 18 A
Compressor: TFH2511Z / TFH2511Z, Refrigerants R404A/R23
Model designation of the CTS cabinet series is structured as follows:
e.g., Type T -55/1000/Li
1) T stands for: Temperature
2) -55 indicates: minimum temperature -55°C
3) 1000 indicates: 1000-liter test chamber volume
4) Li indicates: special configuration for tests with lithium-ion accumulators
Control:
32-bit controller
LCD control panel
Digital display of set and actual values
Numerical setpoint input
Error messages in plain text
Ethernet interface
RS 232 interface
Free switching channels for customer-side test item control
Test Chamber Lighting:
Energy-efficient, high-intensity LED light bar mounted on the door
Rack:
Stainless steel, usable area 970 x 980 mm
Max. load per rack: 35 kg
Total load with maximum rack installation: 100 kg
Feedthroughs:
1x NW50
2x NW125
2x Rp 3 1/4° for Minimax
Technical Performance Data:
Temperature Testing:
Temperature range: -50°C to +100°C
Fgsdpfxsvba Ras Aguoh
Temperature deviation: ≤ ±0.3 K over time
Temperature change rate according to IEC 60068-3-5
Heating: 2.5 K/min
Cooling: 2.5 K/min
Thermal compensation:
Approx. 4000 W at +20°C
Approx. 2200 W at -40°C
The technical specifications refer to an ambient temperature of +25°C, rated voltage 400V, without test item, thermal compensation, or additional equipment. Options may affect performance data.
Dimensions:
Test volume: 1000 liters
Internal dimensions (approx.): Height 1000 mm, Width 860 mm, Depth 1100 mm
External dimensions (approx.): Height 1950 mm, Width 1270 mm, Depth 1900 mm
Operating Data:
Electrical connection: 400 V +6/-10%, 3/N, 50 Hz
Rated current: 18 A
Rated power: 9.5 kW
Degree of protection: IP 54
Sound pressure level: < 58 dB(A) (measured according to DIN EN ISO 3744 at 1m distance from the front)
Weight approx. 1000 kg
Heat emission to installation area: 10.4 kW
Cooling Unit:
Water-cooled, low-noise, fully hermetic
Stepless power control via electronic monitoring and control system
Environmentally friendly refrigerants R404A/R23
Important Safety Information for Buyers!
The following steps are performed on our offered chambers prior to delivery:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant if required
3. Leak test with certificate
4. Upon successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Technical data subject to change and errors reserved!)
Further questions can be answered by phone.
Inzercia bola automaticky preložená a vyskytli sa nejaké chyby prekladu.
Poskytovateľ
Poznámka: Zaregistrujte sa zadarmo alebo sa prihláste, aby ste získali všetky informácie.
Odoslať žiadosť
Telefón & Fax
+49 2861 ... inzercie
Váš inzerát bol úspešne odstránený
Došlo k chybe