Teplotná skúšobná komoraCTS
TSR-30/1000
Teplotná skúšobná komora
CTS
TSR-30/1000
Stav
Použitý
Umiestnenie
Borken 

Zobraziť obrázky
Zobraziť mapu
Údaje o stroji
Cena a lokalita
- Umiestnenie:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Volať
Podrobnosti ponuky
- ID záznamu:
- A14926978
- Referenčné č.:
- 23988
- Naposledy aktualizované:
- dňa 15.11.2024
Popis
CTS
Model: TSR-30/1000
Water-cooled
The type designation of the CTS cabinet series is composed as follows:
For example, Type TSR-30/1000
1) T stands for: Temperature
2) S stands for: Stress Screening
3) R stands for: External Conditioning
4) -30 signifies: minimum temperature -30°C
5) 1000 signifies: 1000 liters test chamber volume
Technical performance data:
A) TSR-30/1000 base unit without hose connections,
i.e., when used as a standalone temperature test chamber
Temperature tests:
Temperature range: -40°C to +180°C
Final temperature: -45°C
Temperature deviation: ≤ ±0.3 K over time
Temperature change rate according to IEC 60068-3-5
Heating: 6.0 K/min
Cooling: 5.0 K/min
Heat emission:
approx. 5000 W at +20°C
approx. 4200 W at ±0°C
approx. 3000 W at -20°C
Technical data based on ambient temperature +25°C,
Nominal voltage 400V, without test specimen, no irradiation, and without additional equipment.
Airflow volume:
approx. 2000 m³/h
B) TSR-30/1000 base unit with hose connections,
for connection to a customer-supplied external test chamber
Temperature tests:
Temperature range: -30°C to +170°C
Temperature deviation: ≤ ±0.1 to 0.5 K over time
Average temperature change rate,
measured in closed-loop circuit
Heating: 4.0 K/min
Cooling: 4.0 K/min
within the range of +150°C to -10°C
Technical data based on ambient temperature +25°C,
Nominal voltage 400V, without test specimen, no irradiation, without additional equipment,
measured in closed-loop circuit
Note: The customer-supplied external test chamber must be completely sealed and properly insulated; any feedthroughs must be optimally sealed by the customer.
Dimensions:
Test volume: 1,000 liters
Air recirculation port: Ø 200 mm
Test chamber dimensions: Height 900 mm, Width 1,000 mm, Depth 1,100 mm
External dimensions: Height 1,950 mm, Width 1,270 mm, Depth 2,245 mm
Technical design:
Refrigeration unit:
Water-cooled, low-noise, fully hermetic
Infinitely variable power adjustment via
electronic monitoring and control system,
environmentally friendly refrigerant R404A
Door:
Fully opening door, left hinged,
One-hand operation, lockable.
Lhedpfx Aerivfcjf Hop
Insert shelf:
Stainless steel, support surface 970 x 980 mm
Load per shelf max. 35 kg
Maximum total load with full shelf configuration: 100 kg
Test chamber illumination: Halogen lamp 20 W, 12 V
Control:
- 32-bit controller
- LCD control panel
Operating data:
Electrical connection: 400 V +6/-10%, 3/N, 50 Hz
Rated power: 13.3 kW
Protection rating: IP 22
Sound pressure level: < 60 dB(A)
Weight: approx. 850 kg
For your safety as a buyer, please note the following information!
The following procedures are carried out in advance on the chambers we offer:
1. Functional test and replacement of necessary components
2. New fill with legally compliant refrigerant, if necessary
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Technical data subject to alterations and errors. Specifications are non-binding!)
If you have further questions, we will be happy to answer them by phone.
Inzercia bola automaticky preložená a vyskytli sa nejaké chyby prekladu.
Model: TSR-30/1000
Water-cooled
The type designation of the CTS cabinet series is composed as follows:
For example, Type TSR-30/1000
1) T stands for: Temperature
2) S stands for: Stress Screening
3) R stands for: External Conditioning
4) -30 signifies: minimum temperature -30°C
5) 1000 signifies: 1000 liters test chamber volume
Technical performance data:
A) TSR-30/1000 base unit without hose connections,
i.e., when used as a standalone temperature test chamber
Temperature tests:
Temperature range: -40°C to +180°C
Final temperature: -45°C
Temperature deviation: ≤ ±0.3 K over time
Temperature change rate according to IEC 60068-3-5
Heating: 6.0 K/min
Cooling: 5.0 K/min
Heat emission:
approx. 5000 W at +20°C
approx. 4200 W at ±0°C
approx. 3000 W at -20°C
Technical data based on ambient temperature +25°C,
Nominal voltage 400V, without test specimen, no irradiation, and without additional equipment.
Airflow volume:
approx. 2000 m³/h
B) TSR-30/1000 base unit with hose connections,
for connection to a customer-supplied external test chamber
Temperature tests:
Temperature range: -30°C to +170°C
Temperature deviation: ≤ ±0.1 to 0.5 K over time
Average temperature change rate,
measured in closed-loop circuit
Heating: 4.0 K/min
Cooling: 4.0 K/min
within the range of +150°C to -10°C
Technical data based on ambient temperature +25°C,
Nominal voltage 400V, without test specimen, no irradiation, without additional equipment,
measured in closed-loop circuit
Note: The customer-supplied external test chamber must be completely sealed and properly insulated; any feedthroughs must be optimally sealed by the customer.
Dimensions:
Test volume: 1,000 liters
Air recirculation port: Ø 200 mm
Test chamber dimensions: Height 900 mm, Width 1,000 mm, Depth 1,100 mm
External dimensions: Height 1,950 mm, Width 1,270 mm, Depth 2,245 mm
Technical design:
Refrigeration unit:
Water-cooled, low-noise, fully hermetic
Infinitely variable power adjustment via
electronic monitoring and control system,
environmentally friendly refrigerant R404A
Door:
Fully opening door, left hinged,
One-hand operation, lockable.
Lhedpfx Aerivfcjf Hop
Insert shelf:
Stainless steel, support surface 970 x 980 mm
Load per shelf max. 35 kg
Maximum total load with full shelf configuration: 100 kg
Test chamber illumination: Halogen lamp 20 W, 12 V
Control:
- 32-bit controller
- LCD control panel
Operating data:
Electrical connection: 400 V +6/-10%, 3/N, 50 Hz
Rated power: 13.3 kW
Protection rating: IP 22
Sound pressure level: < 60 dB(A)
Weight: approx. 850 kg
For your safety as a buyer, please note the following information!
The following procedures are carried out in advance on the chambers we offer:
1. Functional test and replacement of necessary components
2. New fill with legally compliant refrigerant, if necessary
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Technical data subject to alterations and errors. Specifications are non-binding!)
If you have further questions, we will be happy to answer them by phone.
Inzercia bola automaticky preložená a vyskytli sa nejaké chyby prekladu.
Poskytovateľ
Poznámka: Zaregistrujte sa zadarmo alebo sa prihláste, aby ste získali všetky informácie.
Registrované od: 2012
Odoslať žiadosť
Telefón & Fax
+49 2861 ... inzercie
Váš inzerát bol úspešne odstránený
Došlo k chybe