Cirkulačný chladič -90 až +200°C, 15 kWLauda Prozess-Thermostat
Integral XT 1590 WS
Cirkulačný chladič -90 až +200°C, 15 kW
Lauda Prozess-Thermostat
Integral XT 1590 WS
Pevná cena plus DPH
11 500 €
Rok výroby
2015
Stav
Použitý
Umiestnenie
Borken 

Údaje o stroji
- Označenie stroja:
- Cirkulačný chladič -90 až +200°C, 15 kW
- Výrobca:
- Lauda Prozess-Thermostat
- Model:
- Integral XT 1590 WS
- Rok výroby:
- 2015
- Stav:
- veľmi dobrý (použitý)
Cena a lokalita
Pevná cena plus DPH
11 500 €
- Umiestnenie:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Zavolať
Podrobnosti ponuky
- ID inzerátu:
- A21899498
- Referenčné číslo:
- 25195
- Aktualizácia:
- naposledy dňa 11.05.2026
Popis
LAUDA Integral XT 1590 WS
Manufacturer: LAUDA Dr. R. Wobser GmbH & Co. KG
Model: Integral XT 1590 WS
Order No.: LWP 551
Serial No.: LWP551-15-0010
Year of manufacture: approx. 2015 (derived from serial number)
Design: Process thermostat / recirculating chiller
For sale is a used LAUDA Integral XT 1590 WS temperature control and cooling system for industrial applications in laboratories, research, chemistry, pharmaceuticals, and production.
The unit is suitable for precise temperature control of external circuits, reactors, test benches, and process systems.
Technical data according to the nameplate:
Hnsdpfx Afsy Rmimjzel
Voltage: 400 V / 3~ / PE / 50 Hz
Power consumption: 13.8 kW
Heating capacity: 8.0 kW
Protection class: IP21C
Refrigeration circuit I:
Refrigerant: R404A
Charge: 3.5 kg
Refrigeration circuit II:
Refrigerant: R508A
Charge: 1.75 kg
Technical data according to manufacturer:
Operating temperature range: approx. -90 °C to +200 °C
Cooling capacity: up to approx. 15 kW at +20 °C
Max. pump pressure: approx. 2.9 bar
Max. pump flow rate: approx. 45 l/min
Filling volume: approx. 10.5–17.4 liters
Features:
LAUDA Command control system
Digital temperature regulation
Graphic display / LCD readout
RS232 / RS485 interface
Vario pump
Magnetically coupled pump
Connections for external temperature control circuits
Mobile floor-standing unit
Industrial design
Condition:
Used device with age- and use-related signs of wear.
Visual condition as shown in the pictures.
A full technical inspection under process conditions was not performed.
Scope of delivery:
LAUDA Integral XT 1590 WS
with control unit
Scope of delivery as shown
Dimensions & Weight:
Dimensions (manufacturer’s specifications):
approx. 700 x 550 x 1600 mm (W x D x H)
Weight (manufacturer’s specifications):
approx. 280 kg
Notes:
Inspection available by prior arrangement.
Loading and collection by prior arrangement possible.
Commissioning, maintenance, and connection may only be carried out by qualified personnel.
Commercial sale – sale without warranty.
Subject to change and errors.
Inzerát bol automaticky preložený. Chyby v preklade sú možné.
Manufacturer: LAUDA Dr. R. Wobser GmbH & Co. KG
Model: Integral XT 1590 WS
Order No.: LWP 551
Serial No.: LWP551-15-0010
Year of manufacture: approx. 2015 (derived from serial number)
Design: Process thermostat / recirculating chiller
For sale is a used LAUDA Integral XT 1590 WS temperature control and cooling system for industrial applications in laboratories, research, chemistry, pharmaceuticals, and production.
The unit is suitable for precise temperature control of external circuits, reactors, test benches, and process systems.
Technical data according to the nameplate:
Hnsdpfx Afsy Rmimjzel
Voltage: 400 V / 3~ / PE / 50 Hz
Power consumption: 13.8 kW
Heating capacity: 8.0 kW
Protection class: IP21C
Refrigeration circuit I:
Refrigerant: R404A
Charge: 3.5 kg
Refrigeration circuit II:
Refrigerant: R508A
Charge: 1.75 kg
Technical data according to manufacturer:
Operating temperature range: approx. -90 °C to +200 °C
Cooling capacity: up to approx. 15 kW at +20 °C
Max. pump pressure: approx. 2.9 bar
Max. pump flow rate: approx. 45 l/min
Filling volume: approx. 10.5–17.4 liters
Features:
LAUDA Command control system
Digital temperature regulation
Graphic display / LCD readout
RS232 / RS485 interface
Vario pump
Magnetically coupled pump
Connections for external temperature control circuits
Mobile floor-standing unit
Industrial design
Condition:
Used device with age- and use-related signs of wear.
Visual condition as shown in the pictures.
A full technical inspection under process conditions was not performed.
Scope of delivery:
LAUDA Integral XT 1590 WS
with control unit
Scope of delivery as shown
Dimensions & Weight:
Dimensions (manufacturer’s specifications):
approx. 700 x 550 x 1600 mm (W x D x H)
Weight (manufacturer’s specifications):
approx. 280 kg
Notes:
Inspection available by prior arrangement.
Loading and collection by prior arrangement possible.
Commissioning, maintenance, and connection may only be carried out by qualified personnel.
Commercial sale – sale without warranty.
Subject to change and errors.
Inzerát bol automaticky preložený. Chyby v preklade sú možné.
Odoslať dopyt
Telefón & Fax
+49 2861 ... inzercie
Váš inzerát bol úspešne odstránený
Došlo k chybe