PretváranieSchmitz Walzmaschine
EA2 - 125/200
Pretváranie
Schmitz Walzmaschine
EA2 - 125/200
EXW Pevná cena plus DPH
5 000 €
Rok výroby
1959
Stav
Použitý
Umiestnenie
Schwäbisch Gmünd 

Zobraziť obrázky
Zobraziť mapu
Údaje o stroji
- Označenie stroja:
- Pretváranie
- Výrobca:
- Schmitz Walzmaschine
- Model:
- EA2 - 125/200
- Rok výroby:
- 1959
- Stav:
- pripravené na použitie (použité)
- Funkčnosť:
- obmedzená funkčnosť
Cena a lokalita
EXW Pevná cena plus DPH
5 000 €
- Umiestnenie:
- Katharinenstraße 13-17, 73525 17, Deutschland

Zavolať
Podrobnosti ponuky
- ID inzerátu:
- A21666753
- Aktualizácia:
- naposledy dňa 08.04.2026
Popis
The two-roll precision rolling machine applies a pressure of 26,000 kg and features a roller core diameter of 125 mm as well as a total roller body length of 200 mm. The effective strip width is 175 mm, ensuring uniform distribution across this area. The commission number is 59024, which can be used by the manufacturer to retrieve the exact design drawings.
It intermittently stops after some time. It is suspected that the electrician needs to take this into account:
• Connection type: Three-phase 380V/400V (3 phases + neutral + earth).
• Power socket: Due to the current rating (22.8 A), a CEE 32A socket (red socket) is required.
Iasdoyzh Tbjpfx Ac Njr
• Fuse protection: The motor must be protected with slow-blow fuses (e.g., type C circuit breakers or Neozed fuses) to handle the high inrush current. A 32A (three-pole) protection is recommended.
• Motor protection: A motor protection switch, set to the rated current (here 22.8 A), is mandatory to protect the motor from overload.
Important note: The data (71.5 rpm, 5 Hz) suggests that this is a very slow-running special motor or a motor operated via a frequency inverter. Commissioning should only be carried out by a qualified electrician.
Inzerát bol automaticky preložený. Chyby v preklade sú možné.
It intermittently stops after some time. It is suspected that the electrician needs to take this into account:
• Connection type: Three-phase 380V/400V (3 phases + neutral + earth).
• Power socket: Due to the current rating (22.8 A), a CEE 32A socket (red socket) is required.
Iasdoyzh Tbjpfx Ac Njr
• Fuse protection: The motor must be protected with slow-blow fuses (e.g., type C circuit breakers or Neozed fuses) to handle the high inrush current. A 32A (three-pole) protection is recommended.
• Motor protection: A motor protection switch, set to the rated current (here 22.8 A), is mandatory to protect the motor from overload.
Important note: The data (71.5 rpm, 5 Hz) suggests that this is a very slow-running special motor or a motor operated via a frequency inverter. Commissioning should only be carried out by a qualified electrician.
Inzerát bol automaticky preložený. Chyby v preklade sú možné.
Poskytovateľ
Poznámka: Zaregistrujte sa zadarmo alebo sa prihláste, aby ste získali všetky informácie.
Registrovaný od: 2026
10 Inzeráty online
Odoslať dopyt
Telefón & Fax
+49 7171 ... inzercie
Váš inzerát bol úspešne odstránený
Došlo k chybe


