S 2x AI AS 1310 autosampleromThermo Fisher Scientific
Flash 2000 CHNS O Analyzer
S 2x AI AS 1310 autosamplerom
Thermo Fisher Scientific
Flash 2000 CHNS O Analyzer
Pevná cena plus DPH
6 500 €
Stav
Použitý
Umiestnenie
Borken 

Zobraziť obrázky
Zobraziť mapu
Údaje o stroji
- Označenie stroja:
- S 2x AI AS 1310 autosamplerom
- Výrobca:
- Thermo Fisher Scientific
- Stav:
- veľmi dobrý (použitý)
Cena a lokalita
Pevná cena plus DPH
6 500 €
- Umiestnenie:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Zavolať
Podrobnosti ponuky
- ID inzerátu:
- A21755313
- Referenčné číslo:
- 25147
- Aktualizácia:
- naposledy dňa 20.04.2026
Popis
Thermo Fisher Scientific Flash 2000 CHNS O Analyzer with 2 x AI AS 1310 Autosamplers
For sale is a used Thermo Fisher Scientific Flash 2000 elemental analyzer.
The unit is equipped with two AI AS 1310 autosamplers.
It is designed for automated laboratory operation.
The system is intended for elemental analysis in the laboratory sector.
Sample introduction is handled via the installed autosamplers.
Continuous and fully automated operation is possible.
Equipment and configuration
- Thermo Fisher Scientific Flash 2000
- CHNS O analyzer
- 2 x AI AS 1310 autosamplers
- Front display with status indicators for operational states
- Gas connections for He and O₂
- RS232 and additional device interfaces
- Connections for autosamplers and add-on modules
- Power supply 230 V
- Accessories and parts as shown in the images
Technical data
Manufacturer: Thermo Fisher Scientific
Model: Flash 2000
Device type: Elemental analyzer
Voltage: 230 V AC
Frequency: 50/60 Hz
Fuse: 2 x 6 A
Power: 1400 VA
Autosamplers
Model: AI AS 1310
Supply: 24 V DC
Power: 46 W per unit
Serial numbers: 420126446 and 420126487
Dimensions
Bjdpoy D Sqvefx Aaljwl
Main unit width approx. 55 to 60 cm
Depth approx. 55 to 65 cm
Height approx. 50 to 60 cm
Total width with 2 autosamplers approx. 100 to 120 cm
Weight
Main unit approx. 45 to 60 kg
Autosampler approx. 8 to 12 kg each
Total approx. 60 to 80 kg
Condition
Used, with age- and use-related signs of wear.
Condition as shown in the images.
Scope of delivery
- Flash 2000 Analyzer
- 2 x autosamplers
- Accessories and cables as shown
Notes
- The table shown in the photos is not included in the sale
- All information taken from the type plate or from the depicted unit
- Errors and prior sale excepted
- Please feel free to contact us if you have any questions.
Inzerát bol automaticky preložený. Chyby v preklade sú možné.
For sale is a used Thermo Fisher Scientific Flash 2000 elemental analyzer.
The unit is equipped with two AI AS 1310 autosamplers.
It is designed for automated laboratory operation.
The system is intended for elemental analysis in the laboratory sector.
Sample introduction is handled via the installed autosamplers.
Continuous and fully automated operation is possible.
Equipment and configuration
- Thermo Fisher Scientific Flash 2000
- CHNS O analyzer
- 2 x AI AS 1310 autosamplers
- Front display with status indicators for operational states
- Gas connections for He and O₂
- RS232 and additional device interfaces
- Connections for autosamplers and add-on modules
- Power supply 230 V
- Accessories and parts as shown in the images
Technical data
Manufacturer: Thermo Fisher Scientific
Model: Flash 2000
Device type: Elemental analyzer
Voltage: 230 V AC
Frequency: 50/60 Hz
Fuse: 2 x 6 A
Power: 1400 VA
Autosamplers
Model: AI AS 1310
Supply: 24 V DC
Power: 46 W per unit
Serial numbers: 420126446 and 420126487
Dimensions
Bjdpoy D Sqvefx Aaljwl
Main unit width approx. 55 to 60 cm
Depth approx. 55 to 65 cm
Height approx. 50 to 60 cm
Total width with 2 autosamplers approx. 100 to 120 cm
Weight
Main unit approx. 45 to 60 kg
Autosampler approx. 8 to 12 kg each
Total approx. 60 to 80 kg
Condition
Used, with age- and use-related signs of wear.
Condition as shown in the images.
Scope of delivery
- Flash 2000 Analyzer
- 2 x autosamplers
- Accessories and cables as shown
Notes
- The table shown in the photos is not included in the sale
- All information taken from the type plate or from the depicted unit
- Errors and prior sale excepted
- Please feel free to contact us if you have any questions.
Inzerát bol automaticky preložený. Chyby v preklade sú možné.
Odoslať dopyt
Telefón & Fax
+49 2861 ... inzercie
Tieto inzeráty by vás mohli tiež zaujímať.
Malý inzerát
Freising
586 km
Skenovací elektrónový mikroskop s emisným poľom
JEOLJSM-IT800is
JEOLJSM-IT800is
Malý inzerát
Borken
977 km
Xenónový merač počasia / merač blednutia
AtlasCI3000+ Bewitterungsprüfung
AtlasCI3000+ Bewitterungsprüfung
Malý inzerát
Duxford
1 433 km
Waters Acquity H-Class UPLC
WatersAquity H-Class
WatersAquity H-Class
Malý inzerát
Duxford
1 433 km
Systém Waters ACQUITY UPLC
WatersACQUITY
WatersACQUITY
Váš inzerát bol úspešne odstránený
Došlo k chybe






































































