HPLC (vysko účinná kvapalinová chromatografia)ThermoFisher / Dionex
UltiMate 3000
HPLC (vysko účinná kvapalinová chromatografia)
ThermoFisher / Dionex
UltiMate 3000
pevná cena bez DPH
10 000 €
Stav
Použitý
Umiestnenie
Borken 

Zobraziť obrázky
Zobraziť mapu
Údaje o stroji
- Popis stroja:
- HPLC (vysko účinná kvapalinová chromatografia)
- Výrobca:
- ThermoFisher / Dionex
- Model:
- UltiMate 3000
- Stav:
- použitý
Cena a lokalita
pevná cena bez DPH
10 000 €
- Umiestnenie:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Volať
Podrobnosti ponuky
- ID záznamu:
- A20416260
- Referenčné č.:
- 24837
- Naposledy aktualizované:
- dňa 30.10.2025
Popis
Dionex / ThermoFisher
FLM:
Temperature range: 5–70 °C (max. 15 °C below ambient temperature)
Temperature accuracy: ±0.5 °C
Temperature stability: ±0.1 °C
Temperature precision: ±0.1 °C
Column capacity: Up to 3 columns, max. 30 cm length
Heating time: From 20 to 50 °C in less than 25 min (at 23 °C ambient temperature, ±0.5 °C)
Cooling time: From 50 to 20 °C in less than 35 min (at 23 °C ambient temperature, ±0.5 °C)
Control: All functions software-controlled via USB 1.1
I/O interfaces: 2 digital inputs, 2 programmable relay outputs
Column identification: Electronic identification system for 3 columns
Switching valves: 1 or 2 thermostated microvalves with low dispersion (10 ports or 6 ports)
Flow splitter: Nano, capillary or thermostated micro-flow splitter with flow splitter identification system
Flow control: Electronically controlled and actively balanced flow splitter, independent of solvent composition and back pressure
Column flow range: 50 nL/min to 2.5 mL/min using a predefined splitter and active flow control
Selectable flow ranges: 50 nL/min to 1000 nL/min (using a nano-LC splitter); 0.5 µL/min to 10 µL/min (with a capillary LC splitter); 10 µL/min to 160 µL/min (with a micro LC splitter)
Gradient delay time: Typically < 1.5 min at 200 nL/min to splitter outlet
Max. column pressure: 35 MPa (4900 psi)
Wetted materials: Quartz glass, stainless steel (1.4571, 316L), PEEK; waste line: PTFE, aluminium oxide (Al₂O₃)
Safety features: Humidity sensor, gas sensor, and leakage sensor for the flow control valve
VWD
Optical design: Dual-beam photometer (monochromator), multi-wavelength UV/VIS detector
Light source: VWD-3400RS: Deuterium lamp and tungsten lamp, temperature control for both lamps
Wavelength range: 190 to 900 nm
Tungsten lamp recommended for wavelengths > 600 nm.
Noise:
Iedpfjxtb Efsx Ac Hjik
At one wavelength:
Inzercia bola automaticky preložená a vyskytli sa nejaké chyby prekladu.
FLM:
Temperature range: 5–70 °C (max. 15 °C below ambient temperature)
Temperature accuracy: ±0.5 °C
Temperature stability: ±0.1 °C
Temperature precision: ±0.1 °C
Column capacity: Up to 3 columns, max. 30 cm length
Heating time: From 20 to 50 °C in less than 25 min (at 23 °C ambient temperature, ±0.5 °C)
Cooling time: From 50 to 20 °C in less than 35 min (at 23 °C ambient temperature, ±0.5 °C)
Control: All functions software-controlled via USB 1.1
I/O interfaces: 2 digital inputs, 2 programmable relay outputs
Column identification: Electronic identification system for 3 columns
Switching valves: 1 or 2 thermostated microvalves with low dispersion (10 ports or 6 ports)
Flow splitter: Nano, capillary or thermostated micro-flow splitter with flow splitter identification system
Flow control: Electronically controlled and actively balanced flow splitter, independent of solvent composition and back pressure
Column flow range: 50 nL/min to 2.5 mL/min using a predefined splitter and active flow control
Selectable flow ranges: 50 nL/min to 1000 nL/min (using a nano-LC splitter); 0.5 µL/min to 10 µL/min (with a capillary LC splitter); 10 µL/min to 160 µL/min (with a micro LC splitter)
Gradient delay time: Typically < 1.5 min at 200 nL/min to splitter outlet
Max. column pressure: 35 MPa (4900 psi)
Wetted materials: Quartz glass, stainless steel (1.4571, 316L), PEEK; waste line: PTFE, aluminium oxide (Al₂O₃)
Safety features: Humidity sensor, gas sensor, and leakage sensor for the flow control valve
VWD
Optical design: Dual-beam photometer (monochromator), multi-wavelength UV/VIS detector
Light source: VWD-3400RS: Deuterium lamp and tungsten lamp, temperature control for both lamps
Wavelength range: 190 to 900 nm
Tungsten lamp recommended for wavelengths > 600 nm.
Noise:
Iedpfjxtb Efsx Ac Hjik
At one wavelength:
Inzercia bola automaticky preložená a vyskytli sa nejaké chyby prekladu.
Poskytovateľ
Poznámka: Zaregistrujte sa zadarmo alebo sa prihláste, aby ste získali všetky informácie.
Registrované od: 2012
Odoslať žiadosť
Telefón & Fax
+49 2861 ... inzercie
Tieto inzeráty by vás mohli tiež zaujímať.
Malý inzerát
Győr
187 km
HPLC systém so softvérom - prečítajte si prosím!
Agilent1100
Agilent1100
Malý inzerát
Duxford
1 433 km
HPLC systém Agilent Cary 1260 infinity
Agilent Cary1260 infinity
Agilent Cary1260 infinity
Malý inzerát
Borken
977 km
Hmotnostný spektrometer (zásobník náhradných dielov)
SCIEXAPI 4000
SCIEXAPI 4000
Malý inzerát
Marthalen
827 km
Stolová váha
Mettler ToledoMB60S
Mettler ToledoMB60S
Váš inzerát bol úspešne odstránený