Modular Plant Growth Chambers Fitotron®, Type HGC 1014 V incl. HQI-T and Krypton lighting module
Temperature range: -10°C to +45°C for temperature testing
Test chamber volume: approx. 1300 l
Simpac control system
Network connection
USB port
The Fitotron® HGC series plant growth chambers are based on modular construction. Individual modules can be added or replaced as needed, allowing for adaptation to various applications. They are suitable for plants with high light requirements such as wheat, maize, cotton, rice, and C4 plants.
Lighting: HQI-BT-400 W/D and 100 W
Temperature range: -10°C to +45°C
Temporal temperature deviation: ±0.5 K
Humidity range: 40% to 95%
Dew point range: +4°C to +35°C
Temporal humidity deviation: ±3 to 5% rH
Fresh air up to 7.5 m³/h
Power consumption without fresh air operation at 25°C / 75% rH: approx. 0.8 kW
Specifications for climate testing with irradiation
Temperature range: +10°C to +45°C with light on +10°C to +45°C
Temporal temperature deviation: ±0.5 K
Humidity range: 40% to 95%
Dew point range: +4°C to +35°C
Temporal humidity deviation: ±3 to 5% rH
Humidification and dehumidification system, test chamber made of stainless steel
Internal dimensions: Height 1400 mm Depth 750 mm Width 1270 mm
External dimensions: Height 1985 mm Depth 980 mm Width 2320 mm
External dimensions with lighting module: Height 2450 mm
Single-door design with inspection window
Fjdpfx Agsv Ivn Usuopn
Computer interface
Connection: 3/N/PE 400V ±10% 50Hz
CE marking, mobile, excellent condition
Tube port ∅ 50 mm
Air cooling
Refrigerant: R404A
Weight: approx. 480 kg + 130 kg lighting module
Inzercia bola automaticky preložená a vyskytli sa nejaké chyby prekladu.
Temperature range: -10°C to +45°C for temperature testing
Test chamber volume: approx. 1300 l
Simpac control system
Network connection
USB port
The Fitotron® HGC series plant growth chambers are based on modular construction. Individual modules can be added or replaced as needed, allowing for adaptation to various applications. They are suitable for plants with high light requirements such as wheat, maize, cotton, rice, and C4 plants.
Lighting: HQI-BT-400 W/D and 100 W
Temperature range: -10°C to +45°C
Temporal temperature deviation: ±0.5 K
Humidity range: 40% to 95%
Dew point range: +4°C to +35°C
Temporal humidity deviation: ±3 to 5% rH
Fresh air up to 7.5 m³/h
Power consumption without fresh air operation at 25°C / 75% rH: approx. 0.8 kW
Specifications for climate testing with irradiation
Temperature range: +10°C to +45°C with light on +10°C to +45°C
Temporal temperature deviation: ±0.5 K
Humidity range: 40% to 95%
Dew point range: +4°C to +35°C
Temporal humidity deviation: ±3 to 5% rH
Humidification and dehumidification system, test chamber made of stainless steel
Internal dimensions: Height 1400 mm Depth 750 mm Width 1270 mm
External dimensions: Height 1985 mm Depth 980 mm Width 2320 mm
External dimensions with lighting module: Height 2450 mm
Single-door design with inspection window
Fjdpfx Agsv Ivn Usuopn
Computer interface
Connection: 3/N/PE 400V ±10% 50Hz
CE marking, mobile, excellent condition
Tube port ∅ 50 mm
Air cooling
Refrigerant: R404A
Weight: approx. 480 kg + 130 kg lighting module