Údaje o stroji
- Popis stroja:
- Striekacie zariadenie v komore na testovanie teploty
- Výrobca:
- Vötsch
- Stav:
- veľmi dobrý (použitý)
Cena a lokalita
- Umiestnenie:
- Einsteinstraße 8a, 46325 Borken, DE
Volať
Podrobnosti ponuky
- ID záznamu:
- A18968101
- Referenčné č.:
- 24597
- Naposledy aktualizované:
- dňa 17.04.2025
Popis
Vötsch
Model: VBT 03/500
Air-cooled
Temperature Test Chest with Spray System
Technical Description:
Data for Temperature Testing without Water:
- Temperature range: -30°C to +80°C
- Temperature deviation in steady-state condition according to IEC 60068-3-5, depending on test chamber temperature: temporally ±1K
- Temperature change rate according to IEC 60068-3-5:
- Heating: approx. 2 K/min
- Cooling: approx. 2 K/min
Data for Temperature Testing with Water:
- Temperature range: +5°C to +80°C
- Possible water level: -10 mm to 540 mm
- Water level = -10 mm: water level is below the insert grid
- Water level = 0 mm: water level is at the upper edge of the insert grid
Standard Spray Device Data:
- Number of spray nozzles: 6
- Spray rate per nozzle: 0.5 l/min
Spray Device Data according to EN 539-2, Method B:
- Number of spray nozzles: 6
- Spray rate per nozzle: 4.5 l/min
- Additional flood nozzles: 2
- Spray rate per additional nozzle: 6 l/min
- Compressed air consumption: approx. 3 m³/h
Data for Water Tank with Pre-Conditioning:
- Volume: approx. 2000 l
- Temperature range for pre-conditioning: +5°C to +40°C
- Temperature transition duration:
- Cooling from +18°C to +5°C: approx. 15 h
- Heating from +15°C to +40°C: approx. 10 h
Installation and Operation Data:
- Test chamber (internal): Width 1120 mm x Depth 840 mm x Height 540 mm
- Housing: Width 2700 mm x Depth 1300 mm x Height 1575 mm
- Water tank: Width 1100 mm x Depth 800 mm x Height 2200 mm
- Feedthroughs: 1 x Ø 50 mm, installed on the left
- Test chamber volume: approx. 500 liters
- Refrigerant: R-404a
Electrical Connection:
- Rated voltage: 3/N/PE AC 400V ±10% 50Hz
- Rated power: approx. 26 kW
- Rated current: approx. 44.0 A (neutral loaded)
- Protection: 63 A gG, provided by customer
Dodpfx Agewc Nvgjnjwc
Net Weight: approx. 890 kg
Buyer Information – Safety Notice:
The following points are carried out in advance on our offered chambers:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to changes and errors in technical data and information!)
For further questions, please contact us by phone.
Inzercia bola automaticky preložená a vyskytli sa nejaké chyby prekladu.
Model: VBT 03/500
Air-cooled
Temperature Test Chest with Spray System
Technical Description:
Data for Temperature Testing without Water:
- Temperature range: -30°C to +80°C
- Temperature deviation in steady-state condition according to IEC 60068-3-5, depending on test chamber temperature: temporally ±1K
- Temperature change rate according to IEC 60068-3-5:
- Heating: approx. 2 K/min
- Cooling: approx. 2 K/min
Data for Temperature Testing with Water:
- Temperature range: +5°C to +80°C
- Possible water level: -10 mm to 540 mm
- Water level = -10 mm: water level is below the insert grid
- Water level = 0 mm: water level is at the upper edge of the insert grid
Standard Spray Device Data:
- Number of spray nozzles: 6
- Spray rate per nozzle: 0.5 l/min
Spray Device Data according to EN 539-2, Method B:
- Number of spray nozzles: 6
- Spray rate per nozzle: 4.5 l/min
- Additional flood nozzles: 2
- Spray rate per additional nozzle: 6 l/min
- Compressed air consumption: approx. 3 m³/h
Data for Water Tank with Pre-Conditioning:
- Volume: approx. 2000 l
- Temperature range for pre-conditioning: +5°C to +40°C
- Temperature transition duration:
- Cooling from +18°C to +5°C: approx. 15 h
- Heating from +15°C to +40°C: approx. 10 h
Installation and Operation Data:
- Test chamber (internal): Width 1120 mm x Depth 840 mm x Height 540 mm
- Housing: Width 2700 mm x Depth 1300 mm x Height 1575 mm
- Water tank: Width 1100 mm x Depth 800 mm x Height 2200 mm
- Feedthroughs: 1 x Ø 50 mm, installed on the left
- Test chamber volume: approx. 500 liters
- Refrigerant: R-404a
Electrical Connection:
- Rated voltage: 3/N/PE AC 400V ±10% 50Hz
- Rated power: approx. 26 kW
- Rated current: approx. 44.0 A (neutral loaded)
- Protection: 63 A gG, provided by customer
Dodpfx Agewc Nvgjnjwc
Net Weight: approx. 890 kg
Buyer Information – Safety Notice:
The following points are carried out in advance on our offered chambers:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to changes and errors in technical data and information!)
For further questions, please contact us by phone.
Inzercia bola automaticky preložená a vyskytli sa nejaké chyby prekladu.
Poskytovateľ
Poznámka: Zaregistrujte sa zadarmo alebo sa prihláste, aby ste získali všetky informácie.
Odoslať žiadosť
Telefón & Fax
+49 2861 ... inzercie
Váš inzerát bol úspešne odstránený
Došlo k chybe