Klimatická skúšobná komora s vlhkosťou 190 litrovVötsch
VC 7018 -70 bis 180°C
Klimatická skúšobná komora s vlhkosťou 190 litrov
Vötsch
VC 7018 -70 bis 180°C
Stav
Použitý
Umiestnenie
Borken 

Zobraziť obrázky
Zobraziť mapu
Údaje o stroji
- Popis stroja:
- Klimatická skúšobná komora s vlhkosťou 190 litrov
- Výrobca:
- Vötsch
- Model:
- VC 7018 -70 bis 180°C
- Stav:
- veľmi dobrý (použitý)
Cena a lokalita
- Umiestnenie:
- Einsteinstraße 8a, 46325 Borken, DE
Volať
Podrobnosti ponuky
- ID záznamu:
- A19102186
- Referenčné č.:
- 24623
- Naposledy aktualizované:
- dňa 08.05.2025
Popis
Vötsch
Model: VC 7018
Dsdpfswh Ttmjx Agnoku
Vötsch Climate Test Chamber VC 7018, water-cooled
Control Unit: “Touchpanel”
All control and operating commands can be issued by simply touching the function symbols on the control unit “Touchpanel”.
Leveling Feet
To compensate for uneven floors and to ensure sufficient ventilation of the machine section, the test chamber is equipped with adjustable feet.
Feed-throughs
The test chamber is equipped with feed-throughs on the right and left sides, allowing measurement leads and test devices to be routed into the test space.
Standard configuration feed-throughs:
R1: nominal width 125 mm
L1: nominal width 50 mm
Test Chamber Dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
External Dimensions: Width 870 mm x Depth 1280 mm x Height 1745 mm
Technical data for temperature testing:
Temperature range: -70°C to +180°C
time stability: ±0.1 to ±0.5 K
spatial stability: ±0.5 to ±2.0 K
Temperature change rate according to IEC 60068-3-5
Heating: 4 K/min
Cooling: 2.3 K/min
Technical data for climate testing:
Temperature range: -10°C to +95°C
Humidity range: 10% to 98% RH
temperature deviation (temporal, center of usable space): ±0.1 to ±0.3 K
temperature deviation (spatial): ±0.5 to ±1.0 K
temperature gradient: 1 to 2 K
humidity deviation (temporal, center of usable space): ±1 to ±3 % RH
Electrical connection:
Rated voltage: 3/N/PE AC 400V ±10%, 50Hz
Rated power: 5.9 kW
Rated current: 12.0 A
Connection cable: 3.5 m
Fuse protection: 16 A slow-blow, on-site
Refrigerants: R-404A and R-23
Test chamber volume: approx. 190 liters
Weight: approx. 460 kg net
Buyer Information – For Your Safety!
The following points are carried out in advance on all chambers offered by us:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Specifications subject to change and errors excepted!)
We are happy to answer further questions by phone.
Inzercia bola automaticky preložená a vyskytli sa nejaké chyby prekladu.
Model: VC 7018
Dsdpfswh Ttmjx Agnoku
Vötsch Climate Test Chamber VC 7018, water-cooled
Control Unit: “Touchpanel”
All control and operating commands can be issued by simply touching the function symbols on the control unit “Touchpanel”.
Leveling Feet
To compensate for uneven floors and to ensure sufficient ventilation of the machine section, the test chamber is equipped with adjustable feet.
Feed-throughs
The test chamber is equipped with feed-throughs on the right and left sides, allowing measurement leads and test devices to be routed into the test space.
Standard configuration feed-throughs:
R1: nominal width 125 mm
L1: nominal width 50 mm
Test Chamber Dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
External Dimensions: Width 870 mm x Depth 1280 mm x Height 1745 mm
Technical data for temperature testing:
Temperature range: -70°C to +180°C
time stability: ±0.1 to ±0.5 K
spatial stability: ±0.5 to ±2.0 K
Temperature change rate according to IEC 60068-3-5
Heating: 4 K/min
Cooling: 2.3 K/min
Technical data for climate testing:
Temperature range: -10°C to +95°C
Humidity range: 10% to 98% RH
temperature deviation (temporal, center of usable space): ±0.1 to ±0.3 K
temperature deviation (spatial): ±0.5 to ±1.0 K
temperature gradient: 1 to 2 K
humidity deviation (temporal, center of usable space): ±1 to ±3 % RH
Electrical connection:
Rated voltage: 3/N/PE AC 400V ±10%, 50Hz
Rated power: 5.9 kW
Rated current: 12.0 A
Connection cable: 3.5 m
Fuse protection: 16 A slow-blow, on-site
Refrigerants: R-404A and R-23
Test chamber volume: approx. 190 liters
Weight: approx. 460 kg net
Buyer Information – For Your Safety!
The following points are carried out in advance on all chambers offered by us:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Specifications subject to change and errors excepted!)
We are happy to answer further questions by phone.
Inzercia bola automaticky preložená a vyskytli sa nejaké chyby prekladu.
Poskytovateľ
Poznámka: Zaregistrujte sa zadarmo alebo sa prihláste, aby ste získali všetky informácie.
Odoslať žiadosť
Telefón & Fax
+49 2861 ... inzercie
Tieto inzeráty by vás mohli tiež zaujímať.
malý inzerát

977 km
Klimatická skúšobná komora s vlhkosťou 190 litrov
VötschVC 7018 -70 bis 180°C
VötschVC 7018 -70 bis 180°C
Váš inzerát bol úspešne odstránený
Došlo k chybe