Type: WK3-340/70
Weiss Climate Test Chamber, Water-cooled
Control Unit: "Touch Panel"
All control and operating commands can be executed by simply touching the function icons on the control unit's "touch panel".
Leveling Feet
To compensate for floor irregularities and to provide adequate ventilation for the machinery section, the test chamber is equipped with adjustable feet.
Feedthroughs
The right and left sides of the test chamber are equipped with feedthroughs. Measurement cables and test equipment can be routed into the test compartment through these ports.
Standard feedthroughs installed:
R1: nominal width 125 mm
L1: nominal width 85 mm
Chamber volume: 335 liters
Test compartment dimensions:
Height: 750 mm, Width: 580 mm, Depth: 765 mm
External dimensions:
Height: 1775 mm, Width: 870 mm, Depth: 1600 mm
Data for temperature tests:
Minimum temperature: –72°C
Maximum temperature: +180°C
Temporal temperature deviation: ± 0.1 to ± 0.5 K
Spatial temperature uniformity: ± 0.5 to ± 1.5 K
Temperature change rate (cooling): 3 K/min
Temperature change rate (heating): 3 K/min
Data for climate (humidity) tests:
Temperature range: +10°C to +95°C
Dew point range: -3°C to +94°C
Humidity range: 10 to 98% r.h.
Temporal temperature deviation: ± 0.1 to ± 0.3 K
Spatial temperature uniformity: ± 0.5 to ± 1 K
Temporal humidity deviation: ± 1 to ± 3% r.h.
Operational data:
Test chamber lighting: Halogen bulbs 2 x 24V, 50W
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal current: 16 A
Nominal power: 4.9 kW
Protection (customer side): 16 A slow-blow fuse
Refrigerant: R-452A/R23
Weight: approx. 585 kg
Important information for your security as a buyer!
The following steps are performed in advance on all our offered chambers:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Technical data subject to change and errors excepted!)
Feel free to contact us by phone for further questions.
Gsdpfxsxmg Sdo Aguekc
Inzercia bola automaticky preložená a vyskytli sa nejaké chyby prekladu.
Weiss Climate Test Chamber, Water-cooled
Control Unit: "Touch Panel"
All control and operating commands can be executed by simply touching the function icons on the control unit's "touch panel".
Leveling Feet
To compensate for floor irregularities and to provide adequate ventilation for the machinery section, the test chamber is equipped with adjustable feet.
Feedthroughs
The right and left sides of the test chamber are equipped with feedthroughs. Measurement cables and test equipment can be routed into the test compartment through these ports.
Standard feedthroughs installed:
R1: nominal width 125 mm
L1: nominal width 85 mm
Chamber volume: 335 liters
Test compartment dimensions:
Height: 750 mm, Width: 580 mm, Depth: 765 mm
External dimensions:
Height: 1775 mm, Width: 870 mm, Depth: 1600 mm
Data for temperature tests:
Minimum temperature: –72°C
Maximum temperature: +180°C
Temporal temperature deviation: ± 0.1 to ± 0.5 K
Spatial temperature uniformity: ± 0.5 to ± 1.5 K
Temperature change rate (cooling): 3 K/min
Temperature change rate (heating): 3 K/min
Data for climate (humidity) tests:
Temperature range: +10°C to +95°C
Dew point range: -3°C to +94°C
Humidity range: 10 to 98% r.h.
Temporal temperature deviation: ± 0.1 to ± 0.3 K
Spatial temperature uniformity: ± 0.5 to ± 1 K
Temporal humidity deviation: ± 1 to ± 3% r.h.
Operational data:
Test chamber lighting: Halogen bulbs 2 x 24V, 50W
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal current: 16 A
Nominal power: 4.9 kW
Protection (customer side): 16 A slow-blow fuse
Refrigerant: R-452A/R23
Weight: approx. 585 kg
Important information for your security as a buyer!
The following steps are performed in advance on all our offered chambers:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Technical data subject to change and errors excepted!)
Feel free to contact us by phone for further questions.
Gsdpfxsxmg Sdo Aguekc
Inzercia bola automaticky preložená a vyskytli sa nejaké chyby prekladu.
Poskytovateľ
Poznámka: Zaregistrujte sa zadarmo alebo sa prihláste, aby ste získali všetky informácie.
Odoslať žiadosť
Telefón & Fax
+49 2861 ... inzercie
Váš inzerát bol úspešne odstránený
Došlo k chybe