Klimatická testovacia komora 5500 litrov (5,5 m³)CTS
CW-60/5,5 -60°C bis +100°C
Klimatická testovacia komora 5500 litrov (5,5 m³)
CTS
CW-60/5,5 -60°C bis +100°C
Stav
Použitý
Umiestnenie
Borken 

Zobraziť obrázky
Zobraziť mapu
Údaje o stroji
- Popis stroja:
- Klimatická testovacia komora 5500 litrov (5,5 m³)
- Výrobca:
- CTS
- Stav:
- veľmi dobrý (použitý)
Cena a lokalita
- Umiestnenie:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Volať
Podrobnosti ponuky
- ID záznamu:
- A20699180
- Referenčné č.:
- 24906
- Naposledy aktualizované:
- dňa 08.12.2025
Popis
CTS CW‑60/5.5 – Water-Cooled Climate Test Chamber
The CW‑60/5.5 from CTS GmbH (Climatic Test Systems) is a medium-sized, walk-in or drive-in climate chamber designed for conducting temperature and humidity tests on multiple test items simultaneously.
Device Description
This climate test cell allows the functionality or material properties of a test specimen to be evaluated under the influence of temperature and humidity. Efficient air circulation with a correspondingly high recirculation rate ensures optimal transfer to the test item. The air treatment system is located at the rear of the interior. The main units are housed behind the chamber in a separate frame for optimal accessibility. Control is managed via a separate control cabinet, with the control panel integrated into the cabinet door.
For dehumidification, the test chamber is equipped with a self-regenerating compressed air dryer. Fresh air flushing of the test chamber is possible via a fan.
Technical Specifications:
Temperature Tests:
- Temperature range: -60 °C to +100 °C
- Temperature deviation: ±0.5 to 1 K over time
- Temperature change rate, linear with test item and radiant heat, measured at supply air
- Heating: 2 K/min from -40 °C to +85 °C
- Cooling: 2 K/min from +85 °C to -40 °C
Climate Tests:
- Temperature range: +10 °C to +90 °C
- Humidity range: 10% to 95% r.h.
- Dew point range: +5 °C to +89 °C
- Temperature deviation: ±0.5 K over time
- Humidity deviation: ±1% to ±3% r.h. over time
Technical data refer to ambient temperature of +25 °C, nominal voltage of 400 V, without test item, without heat radiation, and without additional equipment.
Dimensions:
Interior (test/useable space):
- Volume: approx. 5,500 liters (5.5 m³)
- Internal dimensions (approx.): Height: ~2,000 mm, Width: ~2,000 mm, Depth: ~1,400 mm (some variation depending on configuration)
Exterior:
- Height: ~2,300–2,500 mm
- Width: ~2,300–2,600 mm
- Depth: ~1,700–2,200 mm (depending on door, frame, accessories, etc.)
Operating Data:
- Electrical connection: 400 V +6/-10%, 3/N, PE, 50 Hz
- Rated power: 58.3 kW (includes 5 sockets)
- Rated current: 86.0 A
- Protection class: IP 54
Technical Design:
- Refrigeration unit: water-cooled, low-noise, semi-hermetic, stepless power adjustment via electronic monitoring and control system
Fedjx D Abpspfx Abzjgk
- Environmentally friendly refrigerants R 23 / R 404 A
Notes:
- Inspection by appointment possible (46325 Borken)
- Shipping by freight carrier possible – costs & arrangements upon request
- Scope of delivery: (see picture)
- Specifications subject to change and errors excepted!
- For further questions, please contact us by phone.
Inzercia bola automaticky preložená a vyskytli sa nejaké chyby prekladu.
The CW‑60/5.5 from CTS GmbH (Climatic Test Systems) is a medium-sized, walk-in or drive-in climate chamber designed for conducting temperature and humidity tests on multiple test items simultaneously.
Device Description
This climate test cell allows the functionality or material properties of a test specimen to be evaluated under the influence of temperature and humidity. Efficient air circulation with a correspondingly high recirculation rate ensures optimal transfer to the test item. The air treatment system is located at the rear of the interior. The main units are housed behind the chamber in a separate frame for optimal accessibility. Control is managed via a separate control cabinet, with the control panel integrated into the cabinet door.
For dehumidification, the test chamber is equipped with a self-regenerating compressed air dryer. Fresh air flushing of the test chamber is possible via a fan.
Technical Specifications:
Temperature Tests:
- Temperature range: -60 °C to +100 °C
- Temperature deviation: ±0.5 to 1 K over time
- Temperature change rate, linear with test item and radiant heat, measured at supply air
- Heating: 2 K/min from -40 °C to +85 °C
- Cooling: 2 K/min from +85 °C to -40 °C
Climate Tests:
- Temperature range: +10 °C to +90 °C
- Humidity range: 10% to 95% r.h.
- Dew point range: +5 °C to +89 °C
- Temperature deviation: ±0.5 K over time
- Humidity deviation: ±1% to ±3% r.h. over time
Technical data refer to ambient temperature of +25 °C, nominal voltage of 400 V, without test item, without heat radiation, and without additional equipment.
Dimensions:
Interior (test/useable space):
- Volume: approx. 5,500 liters (5.5 m³)
- Internal dimensions (approx.): Height: ~2,000 mm, Width: ~2,000 mm, Depth: ~1,400 mm (some variation depending on configuration)
Exterior:
- Height: ~2,300–2,500 mm
- Width: ~2,300–2,600 mm
- Depth: ~1,700–2,200 mm (depending on door, frame, accessories, etc.)
Operating Data:
- Electrical connection: 400 V +6/-10%, 3/N, PE, 50 Hz
- Rated power: 58.3 kW (includes 5 sockets)
- Rated current: 86.0 A
- Protection class: IP 54
Technical Design:
- Refrigeration unit: water-cooled, low-noise, semi-hermetic, stepless power adjustment via electronic monitoring and control system
Fedjx D Abpspfx Abzjgk
- Environmentally friendly refrigerants R 23 / R 404 A
Notes:
- Inspection by appointment possible (46325 Borken)
- Shipping by freight carrier possible – costs & arrangements upon request
- Scope of delivery: (see picture)
- Specifications subject to change and errors excepted!
- For further questions, please contact us by phone.
Inzercia bola automaticky preložená a vyskytli sa nejaké chyby prekladu.
Poskytovateľ
Poznámka: Zaregistrujte sa zadarmo alebo sa prihláste, aby ste získali všetky informácie.
Registrované od: 2012
Odoslať žiadosť
Telefón & Fax
+49 2861 ... inzercie
Tieto inzeráty by vás mohli tiež zaujímať.
malý inzerát
Borken
977 km
Klimatická testovacia komora 5500 litrov (5,5 m³)
CTSCW-60/5,5 -60°C bis +100°C
CTSCW-60/5,5 -60°C bis +100°C
malý inzerát
Borken
977 km
Klimatická testovacia komora 5500 litrov (5,5 m³)
CTSCW-60/5,5 -60°C bis +100°C
CTSCW-60/5,5 -60°C bis +100°C
Váš inzerát bol úspešne odstránený
Došlo k chybe