Teplotná skúšobná komora chránenáCTS
T-30/950 Ex/I
Teplotná skúšobná komora chránená
CTS
T-30/950 Ex/I
Rok výroby
2011
Stav
Použitý
Umiestnenie
Borken 

Zobraziť obrázky
Zobraziť mapu
Údaje o stroji
- Popis stroja:
- Teplotná skúšobná komora chránená
- Výrobca:
- CTS
- Model:
- T-30/950 Ex/I
- Rok výroby:
- 2011
- Stav:
- veľmi dobrý (použitý)
Cena a lokalita
- Umiestnenie:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Volať
Podrobnosti ponuky
- ID záznamu:
- A7538378
- Referenčné č.:
- 23117
- Naposledy aktualizované:
- dňa 27.06.2025
Popis
CTS
Type: T-30/950 Ex/I
CTS Temperature Test Chamber - Explosion-Proof
Control: 32-bit controller
LCD control panel
Digital display of set and actual values
Numeric input of set values
Error messages in plain text
Interface: RS 232
Free switching channels for customer-specific test specimen control
Temperature Testing:
Temperature range: -30°C to +80°C
Temperature deviation: ±0.3 K over time
Temperature change rate:
Heating: 2 K/min
Cooling: 1.5 K/min down to -10°C
Heat output: approx. 1000 W at +20°C
approx. 200 W at -25°C
Nitrogen inertization with residual oxygen monitoring:
The test chamber is initially purged with a large N2 flow rate until the oxygen content drops below 3%. Afterwards, it switches to a base load amount (approx. 10% of the purge quantity).
The nitrogen base load flow is measured, displayed and monitored via a flow meter and limit switch.
The O2 monitoring system continuously draws gas from the test chamber through a flame arrestor and passes it over an O2 sensor to monitor the residual oxygen content. The gas is then returned to the test chamber via a second flame arrestor. The extraction pump is monitored with a flow meter. Further details are provided in the Dräger operating manual in the appendix.
The gas system is currently deactivated!
Kedpfx Aoihb Amec Henf
Technical data refer to an ambient temperature of +25°C, rated voltage 400V, without test specimen, without radiation, and without additional equipment.
Dimensions:
Test volume: 950 liters
Test chamber dimensions: height approx. 700 mm / width approx. 900 mm / depth approx. 1500 mm
External dimensions: height approx. 2400 mm / width approx. 1270 mm / depth approx. 3125 mm
Operating data:
Electrical connection: 400V +6/-10%, 3/N, 50 Hz
Rated power: 21.6 kW
Rated current: 36.5 A
Protection class: IP 54
Condensate drain: non-pressurized, R 1/2" female thread
Sound pressure level: < 62 dB(A)
(measured according to DIN EN ISO 3744 at 1m distance from front)
Weight: approx. 1500 kg, switch cabinet approx. 300 kg
External refrigeration unit
Refrigerants: R404A / R23
Buyer safety information!
The following points are carried out in advance on the chambers we offer:
1. Functional check and replacement of necessary components
2. Recharge with legally compliant refrigerant if necessary
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Subject to changes and errors in the technical data and specifications!)
We are happy to answer further questions by phone.
Inzercia bola automaticky preložená a vyskytli sa nejaké chyby prekladu.
Type: T-30/950 Ex/I
CTS Temperature Test Chamber - Explosion-Proof
Control: 32-bit controller
LCD control panel
Digital display of set and actual values
Numeric input of set values
Error messages in plain text
Interface: RS 232
Free switching channels for customer-specific test specimen control
Temperature Testing:
Temperature range: -30°C to +80°C
Temperature deviation: ±0.3 K over time
Temperature change rate:
Heating: 2 K/min
Cooling: 1.5 K/min down to -10°C
Heat output: approx. 1000 W at +20°C
approx. 200 W at -25°C
Nitrogen inertization with residual oxygen monitoring:
The test chamber is initially purged with a large N2 flow rate until the oxygen content drops below 3%. Afterwards, it switches to a base load amount (approx. 10% of the purge quantity).
The nitrogen base load flow is measured, displayed and monitored via a flow meter and limit switch.
The O2 monitoring system continuously draws gas from the test chamber through a flame arrestor and passes it over an O2 sensor to monitor the residual oxygen content. The gas is then returned to the test chamber via a second flame arrestor. The extraction pump is monitored with a flow meter. Further details are provided in the Dräger operating manual in the appendix.
The gas system is currently deactivated!
Kedpfx Aoihb Amec Henf
Technical data refer to an ambient temperature of +25°C, rated voltage 400V, without test specimen, without radiation, and without additional equipment.
Dimensions:
Test volume: 950 liters
Test chamber dimensions: height approx. 700 mm / width approx. 900 mm / depth approx. 1500 mm
External dimensions: height approx. 2400 mm / width approx. 1270 mm / depth approx. 3125 mm
Operating data:
Electrical connection: 400V +6/-10%, 3/N, 50 Hz
Rated power: 21.6 kW
Rated current: 36.5 A
Protection class: IP 54
Condensate drain: non-pressurized, R 1/2" female thread
Sound pressure level: < 62 dB(A)
(measured according to DIN EN ISO 3744 at 1m distance from front)
Weight: approx. 1500 kg, switch cabinet approx. 300 kg
External refrigeration unit
Refrigerants: R404A / R23
Buyer safety information!
The following points are carried out in advance on the chambers we offer:
1. Functional check and replacement of necessary components
2. Recharge with legally compliant refrigerant if necessary
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Subject to changes and errors in the technical data and specifications!)
We are happy to answer further questions by phone.
Inzercia bola automaticky preložená a vyskytli sa nejaké chyby prekladu.
Poskytovateľ
Poznámka: Zaregistrujte sa zadarmo alebo sa prihláste, aby ste získali všetky informácie.
Registrované od: 2012
Odoslať žiadosť
Telefón & Fax
+49 2861 ... inzercie
Tieto inzeráty by vás mohli tiež zaujímať.
Malý inzerát
Tata
155 km
Kondenzátor chladiča kvapaliny
Güntner GVH 090.1.D/5-M(D)680,4 /579,2 kw
Güntner GVH 090.1.D/5-M(D)680,4 /579,2 kw
Malý inzerát
Hochdorf
751 km
Chladiaca jednotka teploty (TCU)
SingleCompact WK3-160-9-50 (IM160F)
SingleCompact WK3-160-9-50 (IM160F)
Malý inzerát
Berlin
618 km
Axiálny kondenzátor
Güntner AGGVH 100.2A/2x3-J(D)
Güntner AGGVH 100.2A/2x3-J(D)
Malý inzerát
Forst
815 km
100 m³ vyrovnávacia nádrž, 3 bar, izolovaná
Malý inzerát
Delmenhorst
913 km
1000L Tlaková nádrž Vyrovnávacia nádrž
10539
10539
Malý inzerát
Schmölln
581 km
Chladiaca miestnosť
Dresdner Kühlanlagenbau
Dresdner Kühlanlagenbau
Malý inzerát
Niedźwiedź
107 km
Dvojstupňová kompresorová jednotka
BitzerS6G-25.2Y (x4)
BitzerS6G-25.2Y (x4)
Malý inzerát
Nattheim
695 km
Stojaca panelová píla
Holz-Her1255
Holz-Her1255
Malý inzerát
Borken
977 km
Klimatická skúšobná komora s vlhkosťou 1000 litrov
CTSC-40/1000 -40°C bis +180°C
CTSC-40/1000 -40°C bis +180°C
Malý inzerát
Wiefelstede
958 km
Ventilačný systém
HeimerWK-61
HeimerWK-61
Váš inzerát bol úspešne odstránený
Došlo k chybe




























































































