Popis
CTS
Model: T-40/2000
Air-cooled Temperature Test Chamber
Technical Specifications:
Cooling Unit:
Air-cooled, low-noise, fully hermetic compressor, stepless capacity control via electronic monitoring and control system, eco-friendly refrigerant R404A.
Door:
Fully openable door, left-hinged, single-handed operation, lockable.
Shelf:
Stainless steel, support surface 970 x 980 + 500 mm
Load per shelf max. 35 kg
Total load with maximum shelves: 100 kg
Test Chamber Lighting: 3x halogen lamp 20 W, 12 V
Control:
32-bit controller
LCD control panel
Digital display of setpoints and actual values
Numerical input of setpoints
Error messages in plain text
RS 232 interface
Free switching channels for user-side test specimen control
Temperature Range: -40°C to +180°C
Rated Voltage: 400V 3/N 50Hz
Csdpfx Asup T Uqjfasrh
Rated Power: 10.4 kW
Rated Current: 17.2 A
Compressor: TFH2516Z
Duct Feedthrough NW 50
Control Panel
Window: 570x710 mm
Electrical connection, cable length 5m
Technical Performance Data:
Temperature Testing:
Temperature range -40°C to +180°C
Temperature deviation ≤ ±0.3 K over time
Temperature change rate according to IEC 60068-3-5
Heating: 2.5 K/min
Cooling: 1.5 K/min
Heat Radiation:
Approx. 2500 W at +20°C
Approx. 2100 W at ± 0°C
Approx. 1500 W at -20°C
Technical data refer to an ambient temperature of +25°C, rated voltage 400V, without test specimen, without incoming radiation, and without additional equipment.
Dimensions:
Test volume: 2000 liters
Internal dimensions: Height 900, Width 975, Depth 2200 mm
External dimensions: Height 1950, Width 1290, Depth 3145 mm
Operating Data:
Electrical connection: 400 V +6/-10 %, 3/N, 50 Hz
Rated power: 17.2 kW
Protection class: IP 22
Condensate drain, non-pressurized R 1/2" female thread
Sound pressure level (measured at 1 m from the front, according to DIN EN ISO 3744): < 55 dB(A)
Weight: approx. 1200 kg
For your safety as a buyer, please note the following information! The following measures are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data and specifications are reserved!)
We are happy to answer any further questions by phone.
Inzercia bola automaticky preložená a vyskytli sa nejaké chyby prekladu.
Model: T-40/2000
Air-cooled Temperature Test Chamber
Technical Specifications:
Cooling Unit:
Air-cooled, low-noise, fully hermetic compressor, stepless capacity control via electronic monitoring and control system, eco-friendly refrigerant R404A.
Door:
Fully openable door, left-hinged, single-handed operation, lockable.
Shelf:
Stainless steel, support surface 970 x 980 + 500 mm
Load per shelf max. 35 kg
Total load with maximum shelves: 100 kg
Test Chamber Lighting: 3x halogen lamp 20 W, 12 V
Control:
32-bit controller
LCD control panel
Digital display of setpoints and actual values
Numerical input of setpoints
Error messages in plain text
RS 232 interface
Free switching channels for user-side test specimen control
Temperature Range: -40°C to +180°C
Rated Voltage: 400V 3/N 50Hz
Csdpfx Asup T Uqjfasrh
Rated Power: 10.4 kW
Rated Current: 17.2 A
Compressor: TFH2516Z
Duct Feedthrough NW 50
Control Panel
Window: 570x710 mm
Electrical connection, cable length 5m
Technical Performance Data:
Temperature Testing:
Temperature range -40°C to +180°C
Temperature deviation ≤ ±0.3 K over time
Temperature change rate according to IEC 60068-3-5
Heating: 2.5 K/min
Cooling: 1.5 K/min
Heat Radiation:
Approx. 2500 W at +20°C
Approx. 2100 W at ± 0°C
Approx. 1500 W at -20°C
Technical data refer to an ambient temperature of +25°C, rated voltage 400V, without test specimen, without incoming radiation, and without additional equipment.
Dimensions:
Test volume: 2000 liters
Internal dimensions: Height 900, Width 975, Depth 2200 mm
External dimensions: Height 1950, Width 1290, Depth 3145 mm
Operating Data:
Electrical connection: 400 V +6/-10 %, 3/N, 50 Hz
Rated power: 17.2 kW
Protection class: IP 22
Condensate drain, non-pressurized R 1/2" female thread
Sound pressure level (measured at 1 m from the front, according to DIN EN ISO 3744): < 55 dB(A)
Weight: approx. 1200 kg
For your safety as a buyer, please note the following information! The following measures are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data and specifications are reserved!)
We are happy to answer any further questions by phone.
Inzercia bola automaticky preložená a vyskytli sa nejaké chyby prekladu.
Poskytovateľ
Poznámka: Zaregistrujte sa zadarmo alebo sa prihláste, aby ste získali všetky informácie.
Odoslať žiadosť
Telefón & Fax
+49 2861 ... inzercie
Váš inzerát bol úspešne odstránený
Došlo k chybe