Klimatická skúšobná komora s vlhkosťouWeiss -72°C bis +180°C
WK3-340/70
Klimatická skúšobná komora s vlhkosťou
Weiss -72°C bis +180°C
WK3-340/70
Stav
Použitý
Umiestnenie
Borken 

Zobraziť obrázky
Zobraziť mapu
Údaje o stroji
- Popis stroja:
- Klimatická skúšobná komora s vlhkosťou
- Výrobca:
- Weiss -72°C bis +180°C
- Model:
- WK3-340/70
- Stav:
- veľmi dobrý (použitý)
Cena a lokalita
- Umiestnenie:
- Einsteinstraße 8a, 46325 Borken, DE
Volať
Podrobnosti ponuky
- ID záznamu:
- A18791221
- Referenčné č.:
- 24566
- Naposledy aktualizované:
- dňa 02.07.2025
Popis
Weiss
Type: WK3-340/70
Weiss Climate Test Chamber, Air-Cooled
Control Unit: Touch Panel
All control and operation commands can be triggered by simply touching the function icons on the “Touch Panel” control unit.
Leveling Feet
To compensate for floor unevenness and to ensure adequate ventilation of the machine section, the test chamber is equipped with adjustable feet.
Ports
The test chamber is equipped with ports on both the right and left sides. These allow measurement cables and test equipment to be routed into the test chamber.
Standard fitted ports:
Dwsdpfx Aev Sr Hzognsc
R1: DN 125 mm
L1: DN 85 mm
Volume: 335 liters
Test Chamber Dimensions:
Internal dimensions: Height 750 mm, Width 580 mm, Depth 765 mm
External dimensions: Height 1775 mm, Width 870 mm, Depth 1600 mm
Data for Temperature Tests:
Minimum temperature: –72°C
Maximum temperature: +180°C
Temporal temperature deviation: ± 0.1 to ± 0.5 K
Spatial temperature homogeneity: ± 0.5 to ± 1.5 K
Temperature change rate, cooling: 3 K/min
Temperature change rate, heating: 3 K/min
Data for Climate Tests:
Temperature range: +10°C to +95°C
Dew point range: -3°C to +94°C
Humidity range: 10 to 98% rH
Temporal temperature deviation: ± 0.1 to ± 0.3 K
Spatial temperature homogeneity: ± 0.5 to ± 1 K
Temporal humidity deviation: ± 1 to ± 3% rH
Operational Data:
Test chamber lighting: Halogen lamp 2 x 24V, 50W
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated current: 16 A
Rated power: 4.9 kW
Customer side fuse: 16 A slow-blow
Refrigerant: R-452A/R23
Weight: approx. 585 kg
Important information for you as a buyer:
The following steps are proactively carried out on all chambers offered by us:
1. Function check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. Upon successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Specifications subject to change and errors excepted!)
For further questions, please feel free to contact us by phone.
Inzercia bola automaticky preložená a vyskytli sa nejaké chyby prekladu.
Type: WK3-340/70
Weiss Climate Test Chamber, Air-Cooled
Control Unit: Touch Panel
All control and operation commands can be triggered by simply touching the function icons on the “Touch Panel” control unit.
Leveling Feet
To compensate for floor unevenness and to ensure adequate ventilation of the machine section, the test chamber is equipped with adjustable feet.
Ports
The test chamber is equipped with ports on both the right and left sides. These allow measurement cables and test equipment to be routed into the test chamber.
Standard fitted ports:
Dwsdpfx Aev Sr Hzognsc
R1: DN 125 mm
L1: DN 85 mm
Volume: 335 liters
Test Chamber Dimensions:
Internal dimensions: Height 750 mm, Width 580 mm, Depth 765 mm
External dimensions: Height 1775 mm, Width 870 mm, Depth 1600 mm
Data for Temperature Tests:
Minimum temperature: –72°C
Maximum temperature: +180°C
Temporal temperature deviation: ± 0.1 to ± 0.5 K
Spatial temperature homogeneity: ± 0.5 to ± 1.5 K
Temperature change rate, cooling: 3 K/min
Temperature change rate, heating: 3 K/min
Data for Climate Tests:
Temperature range: +10°C to +95°C
Dew point range: -3°C to +94°C
Humidity range: 10 to 98% rH
Temporal temperature deviation: ± 0.1 to ± 0.3 K
Spatial temperature homogeneity: ± 0.5 to ± 1 K
Temporal humidity deviation: ± 1 to ± 3% rH
Operational Data:
Test chamber lighting: Halogen lamp 2 x 24V, 50W
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated current: 16 A
Rated power: 4.9 kW
Customer side fuse: 16 A slow-blow
Refrigerant: R-452A/R23
Weight: approx. 585 kg
Important information for you as a buyer:
The following steps are proactively carried out on all chambers offered by us:
1. Function check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. Upon successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Specifications subject to change and errors excepted!)
For further questions, please feel free to contact us by phone.
Inzercia bola automaticky preložená a vyskytli sa nejaké chyby prekladu.
Poskytovateľ
Poznámka: Zaregistrujte sa zadarmo alebo sa prihláste, aby ste získali všetky informácie.
Odoslať žiadosť
Telefón & Fax
+49 2861 ... inzercie
Váš inzerát bol úspešne odstránený
Došlo k chybe