Klimatická skúšobná komora s vlhkosťouWeiss -72°C bis +180°C
WK3-340/70
Klimatická skúšobná komora s vlhkosťou
Weiss -72°C bis +180°C
WK3-340/70
Stav
Použitý
Umiestnenie
Borken 

Údaje o stroji
- Označenie stroja:
- Klimatická skúšobná komora s vlhkosťou
- Výrobca:
- Weiss -72°C bis +180°C
- Model:
- WK3-340/70
- Stav:
- veľmi dobrý (použitý)
Cena a lokalita
- Umiestnenie:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Zavolať
Podrobnosti ponuky
- ID inzerátu:
- A18791221
- Referenčné číslo:
- 24566
- Aktualizácia:
- naposledy dňa 02.07.2025
Popis
Weiss
Type: WK3-340/70
Weiss Climate Test Chamber, Air-Cooled
Control Unit: Touch Panel
All control and operation commands can be triggered by simply touching the function icons on the “Touch Panel” control unit.
Leveling Feet
To compensate for floor unevenness and to ensure adequate ventilation of the machine section, the test chamber is equipped with adjustable feet.
Ports
The test chamber is equipped with ports on both the right and left sides. These allow measurement cables and test equipment to be routed into the test chamber.
Standard fitted ports:
R1: DN 125 mm
L1: DN 85 mm
Volume: 335 liters
Test Chamber Dimensions:
Internal dimensions: Height 750 mm, Width 580 mm, Depth 765 mm
External dimensions: Height 1775 mm, Width 870 mm, Depth 1600 mm
Data for Temperature Tests:
Minimum temperature: –72°C
Maximum temperature: +180°C
Temporal temperature deviation: ± 0.1 to ± 0.5 K
Spatial temperature homogeneity: ± 0.5 to ± 1.5 K
Temperature change rate, cooling: 3 K/min
Temperature change rate, heating: 3 K/min
Bjdpfx Adjv Sr Hzjiodc
Data for Climate Tests:
Temperature range: +10°C to +95°C
Dew point range: -3°C to +94°C
Humidity range: 10 to 98% rH
Temporal temperature deviation: ± 0.1 to ± 0.3 K
Spatial temperature homogeneity: ± 0.5 to ± 1 K
Temporal humidity deviation: ± 1 to ± 3% rH
Operational Data:
Test chamber lighting: Halogen lamp 2 x 24V, 50W
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated current: 16 A
Rated power: 4.9 kW
Customer side fuse: 16 A slow-blow
Refrigerant: R-452A/R23
Weight: approx. 585 kg
Important information for you as a buyer:
The following steps are proactively carried out on all chambers offered by us:
1. Function check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. Upon successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Specifications subject to change and errors excepted!)
For further questions, please feel free to contact us by phone.
Inzerát bol automaticky preložený. Chyby v preklade sú možné.
Type: WK3-340/70
Weiss Climate Test Chamber, Air-Cooled
Control Unit: Touch Panel
All control and operation commands can be triggered by simply touching the function icons on the “Touch Panel” control unit.
Leveling Feet
To compensate for floor unevenness and to ensure adequate ventilation of the machine section, the test chamber is equipped with adjustable feet.
Ports
The test chamber is equipped with ports on both the right and left sides. These allow measurement cables and test equipment to be routed into the test chamber.
Standard fitted ports:
R1: DN 125 mm
L1: DN 85 mm
Volume: 335 liters
Test Chamber Dimensions:
Internal dimensions: Height 750 mm, Width 580 mm, Depth 765 mm
External dimensions: Height 1775 mm, Width 870 mm, Depth 1600 mm
Data for Temperature Tests:
Minimum temperature: –72°C
Maximum temperature: +180°C
Temporal temperature deviation: ± 0.1 to ± 0.5 K
Spatial temperature homogeneity: ± 0.5 to ± 1.5 K
Temperature change rate, cooling: 3 K/min
Temperature change rate, heating: 3 K/min
Bjdpfx Adjv Sr Hzjiodc
Data for Climate Tests:
Temperature range: +10°C to +95°C
Dew point range: -3°C to +94°C
Humidity range: 10 to 98% rH
Temporal temperature deviation: ± 0.1 to ± 0.3 K
Spatial temperature homogeneity: ± 0.5 to ± 1 K
Temporal humidity deviation: ± 1 to ± 3% rH
Operational Data:
Test chamber lighting: Halogen lamp 2 x 24V, 50W
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated current: 16 A
Rated power: 4.9 kW
Customer side fuse: 16 A slow-blow
Refrigerant: R-452A/R23
Weight: approx. 585 kg
Important information for you as a buyer:
The following steps are proactively carried out on all chambers offered by us:
1. Function check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. Upon successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Specifications subject to change and errors excepted!)
For further questions, please feel free to contact us by phone.
Inzerát bol automaticky preložený. Chyby v preklade sú možné.
Odoslať dopyt
Telefón & Fax
+49 2861 ... inzercie
Tieto inzeráty by vás mohli tiež zaujímať.
Malý inzerát
Bad Salzungen
726 km
Hviezdicové sito
Butzer - EVRESS / B2
Butzer - EVRESS / B2
Malý inzerát
Torres de la Alameda
2 037 km
Sústruh na CNC
CMZTX 66
CMZTX 66
Malý inzerát
Borken
977 km
Klimatická komora s vlhkosťou 34 litrov
WeissWKL 34/60 -60°C bis 150°C
WeissWKL 34/60 -60°C bis 150°C
Malý inzerát
Nemecko
988 km
Obrábacie centrum - vertikálne
HEDELIUSBC 100/50-2500
HEDELIUSBC 100/50-2500
Malý inzerát
Wallerstein
676 km
CNC sústruh
SpinnerTC400
SpinnerTC400
Malý inzerát
Sremska Mitrovica
411 km
Iba zvukotesná kabína
for BRUDERER pressesSound insulating cabin
for BRUDERER pressesSound insulating cabin
Malý inzerát
Kassel
787 km
Tlač
Massey Ferguson4160 V Protec 25 Messer
Massey Ferguson4160 V Protec 25 Messer
Malý inzerát
Nemecko
875 km
KEYENCE IM-8020
KEYENCEIM-8020
KEYENCEIM-8020
Malý inzerát
Sonsbeck
1 003 km
Univerzálny skúšobný stroj Stroj na skúšanie v ťahu
Hegewald & PeschkeH2,5TMNI
Hegewald & PeschkeH2,5TMNI
Malý inzerát
Hilzingen
815 km
Bruderer BSTA 110
BRUDERERBSTA 110
BRUDERERBSTA 110
Váš inzerát bol úspešne odstránený
Došlo k chybe