Skúšobná komora na nárazové skúškyHeraeus
HT 7012 S2
Skúšobná komora na nárazové skúšky
Heraeus
HT 7012 S2
Stav
Použitý
Umiestnenie
Borken 

Zobraziť obrázky
Zobraziť mapu
Údaje o stroji
- Popis stroja:
- Skúšobná komora na nárazové skúšky
- Výrobca:
- Heraeus
- Model:
- HT 7012 S2
- Stav:
- veľmi dobrý (použitý)
Cena a lokalita
- Umiestnenie:
- Einsteinstraße 8a, 46325 Borken, DE
Volať
Podrobnosti ponuky
- ID záznamu:
- A7619891
- Referenčné č.:
- 23137
- Naposledy aktualizované:
- dňa 15.11.2024
Popis
Heraeus Shock Test Chamber
We are offering a shock test chamber for sale.
Water-cooled thermal shock test cabinet
Two-chamber design
Hot chamber:
The temperature range of the hot chamber is from +50°C to +220°C
Temporal temperature deviation at workspace center: ±1 K
Spatial temperature deviation: ±2 K
Rate of temperature change (heating): 11 K/min
Cold chamber:
The temperature range of the cold chamber is from -65°C to +70°C
Temporal temperature deviation at workspace center: ±1 K
Spatial temperature deviation: ±2 K
Rate of temperature change:
Heating: 2 K/min
Cooling: 3 K/min
Test space volume: 125 liters
Temperature range hot chamber: +50°C to +220°C
Temperature range cold chamber: -80°C to +70°C (please note discrepancy in ranges listed)
Test space dimensions:
Width: 470 mm
Depth: 650 mm
Height: 410 mm
External dimensions:
Width: 930 mm
Depth: 2115 mm
Height: 1970+ mm
Rated power: 10 kW
Fgjdpfx Agsikvlxjujh
Rated current: 25 A
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Refrigerants: R404A / R23
Weight: 1000 kg
Important information for your safety as a buyer!
The following steps are performed on our offered chambers prior to sale:
1. Functional test and replacement of necessary components
2. New filling with legally compliant refrigerant
3. Leak test with inspection certificate
4. After successful inspection, the chambers undergo a trial run monitored with calibrated equipment.
Type: HT 7012 S2
Condition: used
Scope of delivery: (see image)
(Specifications subject to change and error!)
Please feel free to contact us by phone for further questions.
Inzercia bola automaticky preložená a vyskytli sa nejaké chyby prekladu.
We are offering a shock test chamber for sale.
Water-cooled thermal shock test cabinet
Two-chamber design
Hot chamber:
The temperature range of the hot chamber is from +50°C to +220°C
Temporal temperature deviation at workspace center: ±1 K
Spatial temperature deviation: ±2 K
Rate of temperature change (heating): 11 K/min
Cold chamber:
The temperature range of the cold chamber is from -65°C to +70°C
Temporal temperature deviation at workspace center: ±1 K
Spatial temperature deviation: ±2 K
Rate of temperature change:
Heating: 2 K/min
Cooling: 3 K/min
Test space volume: 125 liters
Temperature range hot chamber: +50°C to +220°C
Temperature range cold chamber: -80°C to +70°C (please note discrepancy in ranges listed)
Test space dimensions:
Width: 470 mm
Depth: 650 mm
Height: 410 mm
External dimensions:
Width: 930 mm
Depth: 2115 mm
Height: 1970+ mm
Rated power: 10 kW
Fgjdpfx Agsikvlxjujh
Rated current: 25 A
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Refrigerants: R404A / R23
Weight: 1000 kg
Important information for your safety as a buyer!
The following steps are performed on our offered chambers prior to sale:
1. Functional test and replacement of necessary components
2. New filling with legally compliant refrigerant
3. Leak test with inspection certificate
4. After successful inspection, the chambers undergo a trial run monitored with calibrated equipment.
Type: HT 7012 S2
Condition: used
Scope of delivery: (see image)
(Specifications subject to change and error!)
Please feel free to contact us by phone for further questions.
Inzercia bola automaticky preložená a vyskytli sa nejaké chyby prekladu.
Poskytovateľ
Poznámka: Zaregistrujte sa zadarmo alebo sa prihláste, aby ste získali všetky informácie.
Odoslať žiadosť
Telefón & Fax
+49 2861 ... inzercie
Tieto inzeráty by vás mohli tiež zaujímať.
malý inzerát

977 km
Skúšobná komora na nárazové skúšky
HeraeusHT 7012 S2
HeraeusHT 7012 S2
Váš inzerát bol úspešne odstránený
Došlo k chybe