Teplota testovacej komory -70 °C až +180 °CVötsch
VTS 7018-5 190 Liter
Teplota testovacej komory -70 °C až +180 °C
Vötsch
VTS 7018-5 190 Liter
Stav
Použitý
Umiestnenie
Borken 

Zobraziť obrázky
Zobraziť mapu
Údaje o stroji
- Popis stroja:
- Teplota testovacej komory -70 °C až +180 °C
- Výrobca:
- Vötsch
- Model:
- VTS 7018-5 190 Liter
- Stav:
- veľmi dobrý (použitý)
Cena a lokalita
- Umiestnenie:
- Einsteinstraße 8a, 46325 Borken, DE
Volať
Predaj strojov

Našli ste nový stroj? Teraz premeňte staré na peniaze.
Dosiahnite najlepšiu cenu cez Machineseeker.
Viac o predaji strojov
Viac o predaji strojov
Podrobnosti ponuky
- ID záznamu:
- A19327626
- Referenčné č.:
- 24650
- Naposledy aktualizované:
- dňa 14.08.2025
Popis
Vötsch
Typ: VTS 7018-5
Water-cooled temperature test chamber
System retrofitted for R-452A
Temperature range: -70°C to +180°C
Temporal temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature change rate cooling: 7.5 K/min
Temperature change rate heating: 7.5 K/min
Heat compensation at +20°C: 3000 W
Heat compensation at -20°C: 3000 W
Test chamber dimensions: width 580 mm, depth 450 mm, height 750 mm
External dimensions: width 870 mm, depth 1280 mm, height 1575 mm
Csdpfx Agjwq Iymswsrh
Test chamber volume: 190 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 10.0 kW Rated current: 21 A
Fuse, on-site: 32 A slow-blow
Sound level at 1m distance (free-field measurement): < 69 dB(A)
Side port: 50 cm / 125 cm
Chamber is water-cooled
Refrigerants: R-452A and R 23
Weight: approx. 460 kg
For your safety as the buyer, please note the following information!
The following points are carried out on our offered chambers prior to delivery:
1. Functional inspection and replacement of necessary components
2. If required, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Specifications and technical data subject to modification and errors!)
Should you have any further questions, we are happy to assist you by phone.
Inzercia bola automaticky preložená a vyskytli sa nejaké chyby prekladu.
Typ: VTS 7018-5
Water-cooled temperature test chamber
System retrofitted for R-452A
Temperature range: -70°C to +180°C
Temporal temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature change rate cooling: 7.5 K/min
Temperature change rate heating: 7.5 K/min
Heat compensation at +20°C: 3000 W
Heat compensation at -20°C: 3000 W
Test chamber dimensions: width 580 mm, depth 450 mm, height 750 mm
External dimensions: width 870 mm, depth 1280 mm, height 1575 mm
Csdpfx Agjwq Iymswsrh
Test chamber volume: 190 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 10.0 kW Rated current: 21 A
Fuse, on-site: 32 A slow-blow
Sound level at 1m distance (free-field measurement): < 69 dB(A)
Side port: 50 cm / 125 cm
Chamber is water-cooled
Refrigerants: R-452A and R 23
Weight: approx. 460 kg
For your safety as the buyer, please note the following information!
The following points are carried out on our offered chambers prior to delivery:
1. Functional inspection and replacement of necessary components
2. If required, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Specifications and technical data subject to modification and errors!)
Should you have any further questions, we are happy to assist you by phone.
Inzercia bola automaticky preložená a vyskytli sa nejaké chyby prekladu.
Poskytovateľ
Poznámka: Zaregistrujte sa zadarmo alebo sa prihláste, aby ste získali všetky informácie.
Odoslať žiadosť
Telefón & Fax
+49 2861 ... inzercie
Váš inzerát bol úspešne odstránený
Došlo k chybe