Klimatická komora s vlhkosťou 34 litrovWeiss
WKL 34/60 -60°C bis 150°C
Klimatická komora s vlhkosťou 34 litrov
Weiss
WKL 34/60 -60°C bis 150°C
Stav
Použitý
Umiestnenie
Borken 

Zobraziť obrázky
Zobraziť mapu
Údaje o stroji
Cena a lokalita
- Umiestnenie:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Zavolať
Podrobnosti ponuky
- ID inzerátu:
- A16211179
- Referenčné číslo:
- 24134
- Aktualizácia:
- naposledy dňa 15.11.2024
Popis
Weiss
Model: WKL 34/60
Weiss Climate Chamber, Air-Cooled
Refrigerant converted to R-452A
Temperature range: -60°C to +150°C
Chamber volume: 34 liters
Standard fittings included:
R1 NW 50 mm
L1NW 120 mm
Internal dimensions: Height 310 mm x Width 324 mm x Depth 300 mm
External dimensions: Height 1740 mm x Width 630 mm x Depth 970 mm
Performance data for temperature testing:
Temperature range: -60°C to +150°C
Temperature deviation at steady state (per IEC 60068-3-5):
Temporal temperature fluctuation at chamber center: ±0.3 to ±1 K, ±1 to ±2 K
Spatial temperature deviation (temperature gradient): 2 to 4
Temperature change rate (per IEC 60068-3-5):
Heating: 2.5 K/min
Cooling: 3 K/min
Maximum heat compensation: 550 W
Performance data for climate testing:
Temperature range: +10°C to +95°C
Humidity range: 10 to 98 % RH
Temperature and humidity deviations (steady state, per IEC 60068-3-5):
Temporal temperature fluctuation at chamber center: ±0.3 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±1.5 (temperature gradient): 1 to 3
Temporal humidity fluctuation at chamber center: ±3 to ±5 % RH
Operating data:
Gsdpfxotr Dino Abxobk
Test chamber illumination: 12V, 20W halogen lamp
Rated voltage: 1/N / PE AC 230V ±10% 50 Hz
Rated power: 2.5 kW
Rated current: 11 A
Fuse (site-provided): 16A slow-blow
Heat emission for air-cooled chambers:
Max. heat emission to environment: 1700 W
Refrigerant: R-452A / R23
Weight: 140 kg
For your security as a buyer, the following information:
The following steps are carried out on our offered chambers prior to sale:
1. Functional check and replacement of necessary components
2. If required, new recharge with legally compliant refrigerant
3. Leakage test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Specifications and technical details subject to change and errors reserved!)
For further questions, we are happy to assist you by telephone.
Inzerát bol automaticky preložený. Chyby v preklade sú možné.
Model: WKL 34/60
Weiss Climate Chamber, Air-Cooled
Refrigerant converted to R-452A
Temperature range: -60°C to +150°C
Chamber volume: 34 liters
Standard fittings included:
R1 NW 50 mm
L1NW 120 mm
Internal dimensions: Height 310 mm x Width 324 mm x Depth 300 mm
External dimensions: Height 1740 mm x Width 630 mm x Depth 970 mm
Performance data for temperature testing:
Temperature range: -60°C to +150°C
Temperature deviation at steady state (per IEC 60068-3-5):
Temporal temperature fluctuation at chamber center: ±0.3 to ±1 K, ±1 to ±2 K
Spatial temperature deviation (temperature gradient): 2 to 4
Temperature change rate (per IEC 60068-3-5):
Heating: 2.5 K/min
Cooling: 3 K/min
Maximum heat compensation: 550 W
Performance data for climate testing:
Temperature range: +10°C to +95°C
Humidity range: 10 to 98 % RH
Temperature and humidity deviations (steady state, per IEC 60068-3-5):
Temporal temperature fluctuation at chamber center: ±0.3 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±1.5 (temperature gradient): 1 to 3
Temporal humidity fluctuation at chamber center: ±3 to ±5 % RH
Operating data:
Gsdpfxotr Dino Abxobk
Test chamber illumination: 12V, 20W halogen lamp
Rated voltage: 1/N / PE AC 230V ±10% 50 Hz
Rated power: 2.5 kW
Rated current: 11 A
Fuse (site-provided): 16A slow-blow
Heat emission for air-cooled chambers:
Max. heat emission to environment: 1700 W
Refrigerant: R-452A / R23
Weight: 140 kg
For your security as a buyer, the following information:
The following steps are carried out on our offered chambers prior to sale:
1. Functional check and replacement of necessary components
2. If required, new recharge with legally compliant refrigerant
3. Leakage test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Specifications and technical details subject to change and errors reserved!)
For further questions, we are happy to assist you by telephone.
Inzerát bol automaticky preložený. Chyby v preklade sú možné.
Odoslať dopyt
Telefón & Fax
+49 2861 ... inzercie
Tieto inzeráty by vás mohli tiež zaujímať.
Malý inzerát
Ponitz
576 km
Zvárací robot
OH-au2mateLorch Cobot welding Schweißroboter
OH-au2mateLorch Cobot welding Schweißroboter
Malý inzerát
Metzingen
766 km
Súradnicový merací stroj
WENZELLH 54 CNC
WENZELLH 54 CNC
Malý inzerát
Zuchwil
919 km
Retortová pec na tepelné spracovanie
MUT360/400-1150
MUT360/400-1150
Malý inzerát
Meiningen
699 km
Sušiče lakov, látky na báze rozpúšťadiel
CaldatracCDF 75/75/75-30 elektr. 300°C Umluftofen
CaldatracCDF 75/75/75-30 elektr. 300°C Umluftofen
Malý inzerát
Mouvaux
1 211 km
Stroj na spracovanie mäsa
GEAFormeuse Multi former MLF 400
GEAFormeuse Multi former MLF 400
Malý inzerát
Veenendaal
1 071 km
3D AOI stroj
ViscomS3088 Ultra chrome
ViscomS3088 Ultra chrome
Malý inzerát
Plauen
583 km
CO2 laserový stroj Gravírovací stroj 200W
Pfeifer technologyskylaser skyCUBE M SYNRAD RF CO2 Laser
Pfeifer technologyskylaser skyCUBE M SYNRAD RF CO2 Laser
Malý inzerát
Tallinn
1 242 km
Umiestnenie stroja / P&P
YAMAHAYSM20-2
YAMAHAYSM20-2
Malý inzerát
Neckartailfingen
767 km
Valcová brúska
EMAG WeissEco 200
EMAG WeissEco 200
Malý inzerát
Borken
977 km
Teplotná skúšobná komora 190 L
Heraeus VötschTemp. -70°C bis + 180°C VTS 7018-5
Heraeus VötschTemp. -70°C bis + 180°C VTS 7018-5
Váš inzerát bol úspešne odstránený
Došlo k chybe